sLH sꢂꢄglꢃ ꢀꢄꢆ dꢇꢀl dc/dc cꢈꢄvꢃꢉꢊꢃꢉꢁ
28 VoLt input – 1.5 Watt – pendinꢋ reVision c reLease
Operating COnditiOns and CharaCteristiCs
inhibit
• Active low (output disabled)
‣IꢀH referenced to input common
‣Active low 0.5 V max
iꢄꢌꢇꢊ Vꢈlꢊꢀgꢃ rꢀꢄgꢃ
• 16 to 40 VDC continuous
• 50 V for 50 msec transient
‣Inhibit pin current < 2mA
• Active high (output enabled)
‣Open collector or unconnected
‣Pin voltage 7 to 8 volts, typical (open circuit)
‣Do not apply external pull-up
oꢇꢊꢌꢇꢊ pꢈwꢃꢉ
• 1.5 W
Lꢃꢀꢆ sꢈlꢆꢃꢉꢂꢄg tꢃmꢌꢃꢉꢀꢊꢇꢉꢃ (10 ꢁꢃꢅ ꢌꢃꢉ lꢃꢀꢆ)
• 300°C
sꢊꢈꢉꢀgꢃ tꢃmꢌꢃꢉꢀꢊꢇꢉꢃ rꢀꢄgꢃ (cꢀꢁꢃ)
• –65°C to +150°C
cꢀꢌꢀꢅꢂꢊꢂvꢃ Lꢈꢀꢆ
• Single output models 100 µF
• Dual output models 100 µF
cꢀꢁꢃ oꢌꢃꢉꢀꢊꢂꢄg tꢃmꢌꢃꢉꢀꢊꢇꢉꢃ (tꢅ)
• -55°C to +125°C full power
• -55°C to +135°C absolute
oꢇꢊꢌꢇꢊ Vꢈlꢊꢀgꢃ tꢃmꢌꢃꢉꢀꢊꢇꢉꢃ cꢈꢃffꢂꢅꢂꢃꢄꢊ
• 100 ppm/°C typical
iꢄꢌꢇꢊ ꢊꢈ oꢇꢊꢌꢇꢊ cꢀꢌꢀꢅꢂꢊꢀꢄꢅꢃ
• 100 to 170 pF typical
iꢁꢈlꢀꢊꢂꢈꢄ
• 100 megohm minimum at 500 VDC
• Any pin to case, except case pin
cꢈꢄvꢃꢉꢁꢂꢈꢄ Fꢉꢃqꢇꢃꢄꢅy (kHz), 28 Vꢂꢄ, fꢇll lꢈꢀꢆ
• 25°C, 280 typ
• -55°C to +125°C; 220 min, 320 max
dꢃꢉꢀꢊꢂꢄg oꢇꢊꢌꢇꢊ pꢈwꢃꢉ/cꢇꢉꢉꢃꢄꢊ (tꢅ)
• Linearly from 100% at 125°C to 0% at 135°C
meChaniCal and envirOnmental
sꢅꢉꢃꢃꢄꢂꢄg
sꢂzꢃ (mꢀxꢂmꢇm)
Space Prototype (O), Class H, or Class K Radiation tolerant to
Radiation Hardness Assurance (RHA) levels of “-” (O) or “R”,
per MIL-STD-38534. Interpoint model numbers use an “O” in
the RHA designator position to indicate the “-” (dash) Radiation
Hardness Assurance level of MIL-PRF-38534, which is defined
as “no RHA”.
• 0.980 x 0.805 x 0.270 inches (24.89 x 20.45 x 6.86 mm)
• See case A2 for dimensions.
Wꢃꢂghꢊ (mꢀxꢂmꢇm)
• 12 grams
See “Class H and K, QML Screening” tables, page 10. Available
configurations: OO, HR, KR
www.interpoint.com
Page 2 of 10
Rev C - 20090318 - Pending Revision C Release