欢迎访问ic37.com |
会员登录 免费注册
发布采购

DR24E12 参数 Datasheet PDF下载

DR24E12图片预览
型号: DR24E12
PDF下载: 下载PDF文件 查看货源
内容描述: 6 & 12安培评级 [Ratings of 6 & 12 Amps]
分类和应用:
文件页数/大小: 7 页 / 1085 K
品牌: CRYDOM [ CRYDOM INC., ]
 浏览型号DR24E12的Datasheet PDF文件第1页浏览型号DR24E12的Datasheet PDF文件第3页浏览型号DR24E12的Datasheet PDF文件第4页浏览型号DR24E12的Datasheet PDF文件第5页浏览型号DR24E12的Datasheet PDF文件第6页浏览型号DR24E12的Datasheet PDF文件第7页  
OUTPUT SPECIFICATIONS DC Output (1)
Description
Operating Voltage [VDC]
Maximum Load Current [Adc] (2)
Minimum Load Current [mAdc]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (10ms) [Apk]
On-State resistance at rated current [Ohms]
Min/Max stranded wire
Min/Max solid wire
Weight (typical)
DR06D06
1-60
6
2.5
0.1
0.6
60
0.1
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR10D06
1-100
6
2.5
0.1
0.6
60
0.1
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR06D12
1-60
12
2.5
0.1
0.5
100
0.1
22/14 AWG
22/14 AWG
3.17 oz. (90g)
DR10D12
1-100
12
2.5
0.1
0.5
100
0.1
22/14 AWG
22/14 AWG
3.17 oz. (90g)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range (4)
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Minimum Input Current (5)
Maximum Input Current (5)
Maximum Turn-On Time (6) (7)
Maximum Turn-Off Time (8)
Min/Max stranded/solid wire
DRxxDxx
4.0-32 VDC
4.0 VDC
1.0 VDC
9
11
1/2 Cycle
1/2 Cycle
22/16 AWG
DRxxBxx
90-140 Vrms
90 Vrms
10 Vrms
3
5
20 msec
30 msec
22/16 AWG
DRxxAxx
200-265 Vrms
200 Vrms
90 Vrms
2.5
3.3
20 msec
30 msec
22/16 AWG
DRxxExx
18-36 Vrms
18 Vrms
4 Vrms
3.5
8
20 msec
30 msec
22/16 AWG
GENERAL SPECIFICATIONS (1)
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Recommended Terminal Screw Torque Range:
Parameters
4000Vrms
10
9
Ohms
10 pF
-30ºC to 80ºC
-30ºC to 100ºC
4.4-7.0 in lb (0.5-0.8 Nm)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See Derating Curves
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
4) DC control includes reverse polarity protection.
5) Input circuitry incorporates active current limiter.
6) Turn-on time for DC control random turn-on versions is 0.1 msec
7) Turn-on time for DC output 600µsec
8) Turn-off time for DC output 300µsec