Part No: CC-0601
Description: magnetic buzzer
Date: 8/21/2006
Unit: mm
Page No: 4 of 4
Reliability Tests
Item
Operating (Life Test)
Test Condition
1. Continuous life test:
The part will be subjected to 72 hours at 45°C
with 1.5 V, 3000 Hz applied.
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 10,000 times at room temp.
(+25 ±10°C) with 1.5 V, 3000 Hz applied.
Evaluation Standard
After the test, the part should
meet specifications without any
damage to the appearance or
performance except SPL. After 4
hours at 25°C, the SPL should be
within ±10 dBA of the initial
measurement.
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25±2°C
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
c) Pressure: 860 - 1060 mbar
c) Pressure: 860 - 1060 mbar
Packaging
Each minimum package of products will be in a carton box and it should be clearly marked with the Part Number,
Quantity, and Outgoing Inspection Number. There should be no mechanical damage to the products during
transportation and/or in storage.
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062