欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDMG15008-03A 参数 Datasheet PDF下载

CDMG15008-03A图片预览
型号: CDMG15008-03A
PDF下载: 下载PDF文件 查看货源
内容描述: 微型动圈式扬声器 [micro dynamic speaker]
分类和应用:
文件页数/大小: 5 页 / 374 K
品牌: CUI [ CUI INC ]
 浏览型号CDMG15008-03A的Datasheet PDF文件第1页浏览型号CDMG15008-03A的Datasheet PDF文件第2页浏览型号CDMG15008-03A的Datasheet PDF文件第3页浏览型号CDMG15008-03A的Datasheet PDF文件第5页  
Date: 12/06/2006  
Unit: mm  
Part No: CDMG15008-03A  
Description: micro dynamic speaker  
Page No: 4 of 5  
Mechanical Characteristics  
Item  
Solderability  
Test Condition  
Stripped wires of lead wires are immersed in  
rosin for 5 seconds and then immersed in  
solder bath of +270 ±5°C for 3 ±0.5 seconds.  
The pull force should be applied to double lead  
wire:  
Horizontal 3.0N (0.306kg) for 30 seconds  
Vertical 2.0N (0.204kg) for 30 seconds  
The speaker should be measured after applying  
a vibration amplitude of 1.5 mm with 10 to  
55 Hz band of vibration frequency to each of  
the 3 perpendicular directions for 2 hours.  
The part will be dropped, contained inside a  
normal box, from a height of 75 cm onto a 40  
mm thick wooden board 10 times.  
Evaluation Standard  
90% min. stripped wires will be  
wet with solder.  
(Connector Excepted)  
(Except the edge of the terminal.)  
Lead Wire Pull Strength  
Vibration  
No damage or cutting off.  
No obstacle will be harmful to  
normal operation; damage,  
cracks, rust, and distortions.  
Should not be audible at 1.55 V  
sine wave between Fo ~ 20 KHz.  
Drop Test  
Environment Test  
Item  
Test Condition  
Evaluation Standard  
High temp. test  
After being placed in a chamber at 85°C for  
8 hours.  
Low temp. test  
Humidity test  
After being placed in a chamber at -20°C for  
96 hours.  
After being placed in a chamber at +60°C and  
90% relative humidity for 240 hours.  
The part shall be subjected to 5 cycles. One  
cycle will consist of:  
The speaker will be measured  
after being placed at +25°C for 6  
hours. No obstacle will be harm  
ful to normal operation; damage,  
cracks, rust, and distortions.  
Should not be audible at 1.55 V  
sine wave between Fo ~ 20 KHz.  
The SPL should be within ±3dB  
when compared to the initial  
measurements.  
Temp. cycle test  
Phone: 800.275.4899  
Fax: 503.612.2381  
www.cui.com  
20050 SW 112th Ave.  