PART NUMBER: CPE-755  
DESCRIPTION: panel mount piezo indicators  
MECHANICAL CHARACTERISTICS  
item  
test condition  
Lead terminals are immersed in rosin for  
evaluation standard  
90% min. of the lead terminals  
solderability  
5 seconds and then immersed in solder bath  
of 270 ±5°C for 3 ±1 seconds.  
will be wet with solder  
(except the edge of the terminal).  
soldering heat resistance  
Lead terminals are immersed up to 1.5mm from  
buzzer’s body in solder bath of 300 ±5°C for  
3 ±0.5 seconds or 260 ±5°C for 10 ±1 seconds.  
For 10 seconds, the force of 9.8N (1.0kg) is  
applied to each terminal in axial direction.  
The buzzer shall be measured after applying  
a vibration amplitude of 1.5 mm with 10 to  
55 Hz band of vibration frequency to each of  
the 3 perpendicular directions for 2 hours.  
The part will be dropped from a height of  
75 cm onto a 40 mm thick wooden board 3  
times in 3 axes (X, Y, Z) for a total of 9 drops.  
No interference in operation.  
No damage or cutting off.  
terminal mechanical strength  
vibration  
The value of oscillation  
frequency/current consumption  
should be ±10% of the initial  
measurements. The SPL should  
be within ±10dB compared with  
the initial measurement.  
drop test  
ENVIRONMENT TEST  
item  
test condition  
evaluation standard  
high temp. test  
After being placed in a chamber at +95°C for  
240 hours.  
low temp. test  
humidity test  
After being placed in a chamber at -40°C for  
240 hours.  
After being placed in a chamber at +40°C and  
90±5% relative humidity for 240 hours.  
The part shall be subjected to 5 cycles. One  
cycle will consist of:  
temp. cycle test  
The buzzer will be measured after  
being placed at +25°C for 4  
hours. The value of the  
oscillation frequency/current  
consumption should be ±10%  
compared to the initial  
measurements. The SPL should  
be within ±10dB compared to the  
initial measurements.  
+95  
+25  
+25  
-40  
0.5hr 0.5hr 0.25 0.5hr 0.5hr 0.5hr 0.25  
3hours  
th  
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383