欢迎访问ic37.com |
会员登录 免费注册
发布采购

VAT2-S12-D15-SMT 参数 Datasheet PDF下载

VAT2-S12-D15-SMT图片预览
型号: VAT2-S12-D15-SMT
PDF下载: 下载PDF文件 查看货源
内容描述: DC-DC变换器 [DC-DC Converter]
分类和应用:
文件页数/大小: 3 页 / 125 K
品牌: CUI [ CUI INC ]
 浏览型号VAT2-S12-D15-SMT的Datasheet PDF文件第2页浏览型号VAT2-S12-D15-SMT的Datasheet PDF文件第3页  
1/3
VAT2-SMT Series DC-DC Converter
Rev. 12-2006
Description
Designed to convert fixed volt-
ages into an isolated voltage, the
VAT2-SMT series is well suited for
providing board-mount local sup-
plies in a wide range of applica-
tions, including mixed analog/digi-
tal circuits, test & measurement
equip., process/machine controls,
datacom/telecom fields, etc...
The semi-regulated output can be
followed by 3-terminal regulators
to provide output protection, in
addition to output regulation.
Features
·Isolated 2 W output
·Temperature range: -40°C~+85°C
·Unregulated
·High efficiency to 85%
·Dual voltage output
·Small footprint
·SMT package style
·Industry standard pinout
·UL94-V0 package
·No heatsink required
·1K VDC isolation
·High power density
·No external component required
Model
Number
VAT2-S5-D5-SMT
VAT2-S5-D9-SMT
VAT2-S5-D12-SMT
VAT2-S12-D5-SMT
VAT2-S12-D9-SMT
VAT2-S12-D12-SMT
VAT2-S12-D15-SMT
Input Voltage
Nominal
Range
5 Vdc
5 Vdc
5 Vdc
12 Vdc
12 Vdc
12 Vdc
12 Vdc
4.5~5.5 Vdc
4.5~5.5 Vdc
4.5~5.5 Vdc
10.8~13.2 Vdc
10.8~13.2 Vdc
10.8~13.2 Vdc
10.8~13.2 Vdc
Output
Voltage
±5 Vdc
±9 Vdc
±12 Vdc
±5 Vdc
±9 Vdc
±12 Vdc
±15 Vdc
Output Current
Max.
Min.
±200 mA
±111 mA
±83 mA
±200 mA
±111 mA
±83 mA
±67 mA
±10 mA
±11 mA
±8 mA
±10 mA
±11 mA
±8 mA
±6 mA
Efficiency
82%
83%
84%
83%
84%
84%
85%
Package
Style
SMT
SMT
SMT
SMT
SMT
SMT
SMT
Output Specifications
Item
Output power
Line Regulation
Load Regulation
For Vin change of 1%
10% to 100% full load (5V output)
10% to 100% full load (9V output)
10% to 100% full load (12V output)
10% to 100% full load (15V output)
Output voltage accuracy
Temperature drift
Output ripple
Switching frequency
See tolerance envelope graph
100% load
20 MHz Bandwidth
Full load, nominal input
100
100
0.03
200
%/°C
mVp-p
KHz
Test conditions
Min.
0.2
10
6.5
6.0
6.0
Typ.
Max.
2
1.2
15
15
15
15
Units
W
%
%
%
%
%
Note:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless
otherwise specified.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com