CY2308
Operating Conditions for Industrial Temperature Devices
Parameter
V
DD
T
A
C
L
C
IN
t
PU
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100 MHz
Load Capacitance, from 100 MHz to 133 MHz
Input Capacitance
Description
Min
3.0
–40
–
–
–
0.05
Max
3.6
85
30
15
7
50
Unit
V
°C
pF
pF
pF
ms
Power-up time for all V
DD
s to reach minimum specified voltage
(power ramps must be monotonic)
Electrical Characteristics for Industrial Temperature Devices
Parameter
V
IL
V
IH
I
IL
I
IH
V
OL
V
OH
I
DD
(PD mode)
I
DD
Description
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
Output LOW Voltage
Output HIGH Voltage
Power Down Supply Current
Supply Current
V
IN
= 0V
V
IN
= V
DD
I
OL
= 8 mA (–1, –2, –3, –4)
I
OL
= 12 mA (–1H, –5H)
I
OH
= –8 mA (–1, –2, –3, –4)
I
OH
= –12 mA (–1H, –5H)
REF = 0 MHz
Unloaded outputs, 100 MHz,
Select inputs at V
DD
or GND
Unloaded outputs, 66 MHz REF
(–1, –2, –3, –4)
Unloaded outputs, 66 MHz REF
(–1, –2, –3, –4)
Test Conditions
Min
–
2.0
–
–
–
2.4
–
–
–
–
–
Max
0.8
–
50.0
100.0
0.4
–
25.0
45.0
70(–1H,–5H)
35.0
20.0
Unit
V
V
μA
μA
V
V
μA
mA
mA
mA
mA
Document Number: 38-07146 Rev. *E