欢迎访问ic37.com |
会员登录 免费注册
发布采购

ES51964 参数 Datasheet PDF下载

ES51964图片预览
型号: ES51964
PDF下载: 下载PDF文件 查看货源
内容描述: 双显示 [Dual Display]
分类和应用:
文件页数/大小: 33 页 / 603 K
品牌: CYRUSTEK [ Cyrustek corporation ]
 浏览型号ES51964的Datasheet PDF文件第1页浏览型号ES51964的Datasheet PDF文件第2页浏览型号ES51964的Datasheet PDF文件第3页浏览型号ES51964的Datasheet PDF文件第4页浏览型号ES51964的Datasheet PDF文件第6页浏览型号ES51964的Datasheet PDF文件第7页浏览型号ES51964的Datasheet PDF文件第8页浏览型号ES51964的Datasheet PDF文件第9页  
ES51964(6600counts)  
Dual Display  
Absolute Maximum Ratings  
Characteristic  
Supply Voltage (V- to AGND)  
Analog Input Voltage  
V+  
Rating  
-4V  
V- -0.6 to V+ +0.6  
V+ (AGND/DGND+0.5V)  
AGND/DGND  
AGND/DGND (V- -0.5V)  
V- -0.6 to DGND +0.6  
500mW  
Digital Input  
Power Dissipation. Flat Package  
Operating Temperature  
Storage Temperature  
0to 70℃  
-25to 125℃  
Electrical Characteristics  
TA=25, V- = -3.3V  
Parameter  
Power supply  
Operating supply current  
In DCV mode  
Symbol  
Test Condition  
Min.  
Typ.  
-3.3  
1.8  
5
Max  
Units  
V
mA  
µA  
V-  
IDD  
ISS  
Normal operation  
In sleep mode  
2.5  
10  
Voltage roll-over error  
Voltage nonlinearity  
REV 10Minput resistor  
±0.1 %F.S1  
Best case straight  
NLV  
line  
±0.1 %F.S1  
Input Leakage  
-10  
1
10  
PA  
Zero input reading  
Band-gap reference voltage  
10Minput resistor -000  
100Kresistor  
000  
+000 counts  
VREF between VRH and  
-1.3  
-1.2  
-1.1  
V
AGND  
Open circuit voltage for 660Ω  
measurement  
Open circuit voltage for other Ω  
measurement  
Peak to peak backplane  
drive voltage  
-1.19  
3.0  
-0.97  
3.2  
-3.3  
-1.08  
3.1  
V
V
V
-3.5VV -2.2V  
Between V- pin and  
HOLD, RANGE,  
KEY, FC1-FC5  
BKLIT,MAXMIN  
Between V- pin  
and RS232  
1.2  
11  
Internal pull-high to 0V  
current  
µA  
AC frequency response at 6.600V  
range  
±1%  
40-400  
HZ  
±5%  
400-2000  
LPF auto ON when  
Hz < 500Hz(+3%)  
100Kresister  
Between VRH  
0<TA<70℃  
3dB frequency for LPF mode  
7.5  
kHz  
Reference voltage temperature  
coefficient  
ppm/℃  
TCRF  
100  
-2.02  
-3  
2.02  
3
%F.S  
Capacitance measurement  
accuracy2  
6.6nF – 66mF  
counts  
Note:  
1. Full Scale  
2. When Capacitance measurement (Clamp mode) is selected, the additional error 1% should be included.  
v2.5 09/04/14  
5