ES51955(5000counts)
Dual Display/Inrush
1.2 Dual display V.S. measurement mode
The dual display default mode configuration is shown at the table below.
Main measurement mode
DC voltage
AC voltage
NCV mode
Resistance mode
Capacitance mode
Frequency mode
Continuity Check
Diode mode
Smart RSDC mode
Temperature mode
DCuA mode
First-display
DC voltage
AC voltage
EF
Resistance
Capacitance
Frequency
Resistance
Voltage
R/S/D/C
o
C
N/A
Second-display (defaulted)
N/A
N/A
Electrical field strength
N/A
N/A
Duty cycle
N/A
N/A
N/A
o
F
DCuA
1.3 Push key operation
With dual display, user can use single push key “SEL” to active the Volts and Amps
readings simultaneously.
Push function
First-display
Second-display
SEL in DCV mode
DC Voltage
DCA
1
DCA/Zero
2
(function selection)
See
Fig.1
SEL in ACV mode
AC Voltage
ACA
ACA Hz
3
(function selection)
See
Fig.2
SEL in Smart mode
R/S/D/C auto scan
N/A
(function selection)
see
Fig. 3
Hold
Stop updating
Stop updating
Inrush (waiting state) N/A
Four bars (- - - -)
Inrush (done)
N/A
Inrush value
NOTE:
1.
2.
3.
DCA mode is not available if DIS_DCA (pin108) is pulled to V-.
DCA/Zero means the readings shown on LCD is offset-cancelled readings.
Hz mode is the frequency reading of ACA mode.
v2.3
7
10/06/25