Spec. No. : C510Q8-A
Issued Date : 2003.08.12
Revised Date :
CYStech Electronics Corp.
Page No. : 4/15
Electrical Characteristics (continued)
Parameter
Test Conditions
Symbol
Min. Typ. Max. Unit
Undervoltage Lockout Section
Start Threshold
PL3842A/PL3844A
PL3843A/PL3845A
14.5 16 17.5
7.8 8.4 9.0
V
V
Min Operating Voltage
After Turn-on
PL3842A/PL3844A
8.5
10 11.5
V
PL3843A/PL3845A
7.0 7.6 8.2
PWM Section
Maximum Duty Cycle
PL3842A/PL3843A
PL3844A/PL3845A
94
47
-
96 100
%
%
%
48
-
50
0
Minimum Duty Cycle
Total Standby Current
Start-up Current
VI=6.5V for PL3843A/45A
VI=14V for PL3842A/44A
VPIN 2 = VPIN 3 = 0V
Ist
-
-
-
0.17 0.3
0.17 0.3
mA
mA
mA
V
Operating Supply Current
Zener Voltage
II
VIZ
12
38
17
-
II = 25 mA
30
Notes: 1. Max. package power dissipation limits must be respected; low duty cycle pulse techniques are used during test
maintain Tj as close to Tamb as possible.
2.These parameters, although guaranteed, are not 100% tested in production.
3.Parameter measured at trip point of latch with VPIN 2= 0 .
4.Gain defined as:
∆VPIN 1
, 0 ≤ VPIN 3 ≤ 0.8V
A=
∆VPIN 3
5. Adjust VI above the start threshold before setting at 15V.
PL384XAQ8
CYStek Product Specification