1504
16 15 14 13 12 11 10
9
Lead Material:
Nickel-Iron alloy 42
TIN PLATE
1
2
3
4
5
6
7
8
.900 MAX.
.280
MAX.
.290
MAX.*
*.320 MAX for delays
larger than 500ns
.015 TYP.
.010±.002
.018
TYP.
.070 MAX.
.700±.010
7 Equal spaces
each .100±.010
Non-Accumulative
.350
MAX.
Package Dimensions
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
Ambient Temperature:
Input Pulse:
Source Impedance:
Rise/Fall Time:
Pulse Width
Period
Pulse Width
Period
(TD <= 75ns):
(TD <= 75ns):
(TD > 75ns):
(TD > 75ns):
25 C
±
3 C
High = 3.0V typical
Low = 0.0V typical
50Ω Max.
3.0 ns Max. (measured
at 10% and 90% levels)
PW
IN
= 100ns
PER
IN
= 1000ns
PW
IN
= 2 x T
D
PER
IN
= 10 x T
D
o
o
OUTPUT:
R
load
:
C
load
:
Threshold:
10MΩ
10pf
50% (Rising & Falling)
NOTE:
The above conditions are for test only and do not in any way restrict the operation of the device.
PER
IN
PW
IN
T
RISE
INPUT
SIGNAL
90%
50%
10%
T
FALL
V
IH
90%
50%
10%
V
IL
D
FALL
D
RISE
T
RISE
OUTPUT
SIGNAL
90%
50%
10%
T
FALL
V
OH
90%
50%
10%
V
OL
Timing Diagram For Testing
OUT
PULSE
GENERATOR
TRIG
R
IN
IN
DEVICE UNDER
TEST (DUT)
OUT
IN
TRIG
OSCILLOSCOPE
50
Ω
R
IN
= R
OUT
= Z
LINE
R
OUT
Test Setup
Doc #01006
10/30/01
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com