3010
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
Ambient Temperature:
Input Pulse:
Source Impedance:
Rise/Fall Time:
Pulse Width:
Period:
25 C
±
3 C
High = 1.8V typical
Low = 0.8V typical
50Ω Max.
3.0 ns Max. (measured
at 10% and 90% levels)
PW
IN
= 500ns
PER
IN
= 1000ns
o
o
OUTPUT:
R
load
:
C
load
:
Threshold:
50Ω
<10pf
50% (Rising & Falling)
NOTE:
The above conditions are for test only and do not in any way restrict the operation of the device.
PER
IN
PW
IN
T
RISE
INPUT
SIGNAL
90%
50%
10%
T
FALL
V
IH
90%
50%
10%
V
IL
D
FALL
T
FALL
D
RISE
T
RISE
OUTPUT
SIGNAL
90%
50%
10%
V
OH
90%
50%
10%
V
OL
Timing Diagram For Testing
OUT (50Ω)
PULSE
GENERATOR
TRIG
IN
DEVICE UNDER
TEST (DUT)
+
VC
OUT
IN (50Ω)
TRIG
OSCILLOSCOPE
Test Setup
Doc #04001
8/10/2005
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3