JQ104E
Operation condition
Insulation Resistance
1)
Dielectric Strength
Between contacts
Between contact and coil
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1)
100M
min (at 500VDC)
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
50Hz 1000V
50Hz 2000V
147m/s
2
11ms
10~40Hz double amplitude 1.5mm
8N 4N PC type
235
2
3 0.5s
-40~105
85% (at 40 )
46g
Note: 1). When testing, coil terminals should be connected, If coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Dimensions
5
mm /inch
36
Max.
0.630max.
?7
0.197
1.12
0.044
0.276
50
1.969
39.5
1.555
1.375
35
3.433max.
87.2max.
77.4max.
0.393 1.118
0.669
12.8
17
10
0.504
44.4max.
1.748max.
Dimensions
Cover
1.575max.
0.791
0.346 0.201
0.024
1.375max.
0.031
0.268
0.118
Mounting (Bottom view)
Wiring diagram (Bottom view)
NOTES
1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.
2.382max.
60.5max.
40
Max.
1.575max.
3.047max.
3