M1BS
E158859
20.0×9.8×11.0
Features
DIL Pitch Terminals .High Sensitivity
g
Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VACg
Fully sealed (immersion clearable).
High Reliability bifurcated Contact.
Application for Telecommunication EquipmentfOffice Equipmentf Security Alarm Systemsf Measuring instrumentsf
Medical Monitoring EquipmentfAudio Visual Equipmentf Flight SimulatorfSensor Controlg
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or
Voltage drop
Operation
Electrical
life
Mechanical
2C
PdRu
2A/30VDC; 0.6A/125VAC
60W
125VA
220VDC 250VAC
100m
3y10
5
10
8
Ag Alloy
1y10
5
Min. Switching load 1mA/1V
Reference Value
Max. Switching Current:2A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Coil voltage
VDC
Rated
3
5
6
9
12
24
48
3
5
6
9
12
24
48
Max.
4.2
7.0
8.4
12.3
17.4
34.0
64.9
4.9
8.1
9.7
14.5
19.4
38.9
77.8
Coil resistance
±10%
16
45
66
140
280
1070
3900
22.5
62.5
90
203
360
1440
5760
Pick up voltage
VDC(max)
(70% of rated
voltage )
2.1
3.5
4.2
6.3
8.4
16.8
33.6
2.1
3.5
4.2
6.3
8.4
16.8
33.6
release voltage
VDC(min)
(10% of rated
voltage)
0.3
0.5
0.6
0.9
1.2
2.4
4.8
0.3
0.5
0.6
0.9
1.2
2.4
4.8
Coil
power
W
0.56
0.56
0.55
0.58
0.52
0.54
0.59
0.4
0.4
0.4
0.4
0.4
0.4
0.4
3
1.5
3
1.5
Operate
Time
ms
Release
Time
ms
CAUTION
:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.