欢迎访问ic37.com |
会员登录 免费注册
发布采购

NT90THLAEAC24VSB0.9 参数 Datasheet PDF下载

NT90THLAEAC24VSB0.9图片预览
型号: NT90THLAEAC24VSB0.9
PDF下载: 下载PDF文件 查看货源
内容描述: 体积小,重量轻。线圈功耗低,触点负载。强大的抗休克和抗振动,可靠性高,寿命长。 [Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life.]
分类和应用:
文件页数/大小: 4 页 / 729 K
品牌: DBLECTRO [ DB LECTRO INC ]
 浏览型号NT90THLAEAC24VSB0.9的Datasheet PDF文件第1页浏览型号NT90THLAEAC24VSB0.9的Datasheet PDF文件第3页浏览型号NT90THLAEAC24VSB0.9的Datasheet PDF文件第4页  
Coil Parameter
DC Coil Parameter
RATED VOLTAGE
VDC
RATED
Max
DASH
NUMBERS
COIL
RESISTANCE
±10%
PICK UP
VOLTAGE
VDC(max)
(75%of
rated
voltage)
RELEASE
VOLTAGE
VDC(min)
(10%of
rated
voltage)
COIL
POWER
W
Operate
Time
ms
Release
Time
Ms
003-900
005-900
006-900
009-900
012-900
015-900
018-900
024-900
048-900
110-900
003-600
005-600
006-600
009-600
012-600
015-600
018-600
024-600
048-600
110-600
3
5
6
9
12
15
18
24
48
110
3
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
10
28
40
90
160
250
360
640
2560
13445
15
42
60
135
240
375
540
960
3840
20167
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
0.9
15
10
5
6
9
12
15
18
24
48
110
0.6
15
10
CAUTION
:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M
min (at 500VDC)
Item 7 of IEC255-5
Item 6
Item 6
of IEC255-5
of IEC255-5
50Hz 1500V
50Hz 2500V
200m/s
2
11ms
10~55Hz double amplitude 1.5mm
10N
235’x2’ 3x0.5s
-55~100’
-55~125’
85% (at 40’)
31g Low profile type . 35g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3 Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
107