DC
SERIES
INTRODUCTIONS
SWITCHING TRANSIENT FILTERS
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.40mA
@ 250VAC 50Hz: 0.80mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-ine: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
V
D E
1.Two-stage filters provide high insertion loss
for both line-to-line and line-to-ground emissions
throughout the frequency range.
COMPONENTS
PART NO.
C1 (uF) C2 (pF) L1 (mH) L2 (uH) R (K )
03DCCG5B/W5B
0.47
9.8
160
470
06DCCG5B/W5B
7.8
110
4700
12DCCG5B/W5B
1.0
3.25
50
220
16DCGG5B/W5B/S5B
2.8
43
ELECTRICAL SCHEMATIC
L
L
I
N
E
C1
R
L1
C1
C2
L2
C2
L
O
A
D
L'
SERIES DIMENSIONS
PART NO.
03DCCG5B/W5B
06DCCG5B/W5B
12DCCG5B/W5B
16DCCG5B/W5B/S5B
A
DIMENSIONS IN INCHES/mm
B
C
D
E
F
3.34
84.8
4.49
114.0
5.63
143.0
4.31
109.5
2.05
52.0
2.22
56.5
2.05
52.0
4.72
120.0
2.58
65.6
3.76
95.5
1.54
39.2
1.83
46.4
N
N'
G
G
75.0
4.06
103.0
6.02
152.9
3.90
99.0
2.95
INSERTION LOSS (TYPICAL)
03DCCG5B
06DCCG5B
0 dB
COMMON MODE
COMMON MODE
DIFF. MODE
DIFF. MODE
5.30 1.78
134.7 45.3
2.01
51.0
2.62
66.5
3.39
86.0
2.28
58.0
20 dB
40 dB
60 dB
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15 .50 1.0 5.0 10 30
3A
25
45
55
55
55 35
6A
25
45
50
60
60 40
12A
20
30
40
55
60 25
16A
15
20
30
60
50 30
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A
45
60
60
70
70 50
6A
50
60
60
60
60 50
12A
35
55
60
60
60 45
16A
40
55
55
60
60 50
80 dB
10K
100K
1M
10M
DIFF. MODE
DIFF. MODE
12DCCG5B
16DCCG5B
0 dB
COMMON MODE
COMMON MODE
20 dB
40 dB
60 dB
80 dB
100 dB
10K
A
100K
1M
10M
MECHANICAL CONSTRUCTION
B
0.25
6.30
D
CG5B
6-6
E
0.21
5.30
C