 浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第7页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第8页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第9页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第10页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第12页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第13页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第14页浏览型号DCS4.5S0A0S20PFA的Datasheet PDF文件第15页  
THERMAL CURVES  
THERMAL CONSIDERATIONS  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
Figure 37: Temperature measurement location  
The allowed maximum hot spot temperature is defined at 107  
DCM04S0A0S12 Output Current vs. Ambient Temperature and Air Velocity  
Output Current(A)  
@Vin = 5.0V, Vo=3.3V (Airflow From Pin8 To Pin10)  
12  
Natural  
Convection  
9
6
3
0
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel.  
Thermal Derating  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
Heat can be removed by increasing airflow over the  
module. To enhance system reliability, the power  
module should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit may  
be affected.  
Figure 38: Output current vs. ambient temperature and air  
velocity@Vin=5V, Vout=3.3V(Either Orientation)  
DCM04S0A0S12 Output Current vs. Ambient Temperature and Air Velocity  
Output Current(A)  
@Vin = 3.3V, Vo=2.5V (Airflow From Pin8 To Pin10)  
12  
Natural  
Convection  
PWB  
FANCING PWB  
9
100LFM  
MODULE  
6
3
0
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
SURED BELOW  
THE MODULE  
25  
30  
35  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
Ambient Temperature ()  
AIR FLOW  
Figure 39: Output current vs. ambient temperature and air  
velocity@ Vin=3.3V, Vout=2.5V(Either Orientation)  
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 36: Wind tunnel test setup  
DS_ DCM04S0A0S12PFA_10022013  
E-mail: DCDC@delta.com.tw  
http://www.deltaww.com/dcdc  
P11