ELECTRICAL CHARACTERISTICS CURVES
Vo
Vo
Io
Io
Figure 18:
Typical transient response to step load change at
5A/μS from 100% to 50% of Io, max at 12Vin, 0.75V out (Cout
= 1uF+ 100uF ceramic, 470uF poscap).
Figure 19:
Typical transient response to step load change at
5A/μS from 50% to 100% of Io, max at 12Vin, 0.75V out (Cout =
1uF+ 100uF ceramic, 470uF poscap).
Vo
Vo
Io
Io
Figure 20:
Typical transient response to step load change at
5A/μS from 100% to 50% of Io, max at 12Vin, 1.2V out (Cout =
1uF+ 100uF ceramic, 470uF poscap).
Figure 21:
Typical transient response to step load change at
5A/μS from 100% to 50% of Io, max at 12Vin, 1.2V out (Cout =
1uF+ 100uF ceramic, 470uF poscap).
Vo
Vo
Io
Io
Figure 22:
Typical transient response to step load change at
5A/μS from 100% to 50% of Io, max at 12Vin, 2.5V out (Cout =
1uF+ 100uF ceramic, 470uF poscap).
Figure 23:
Typical transient response to step load change at
5A/μS from 50% to 100% of Io, max at 12Vin, 2.5V out (Cout =
1uF+ 100uF ceramic, 470uF poscap).
PRELIMINARY DS_DNL10SIP20_10132008