 浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第3页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第4页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第5页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第6页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第8页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第9页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第10页浏览型号DNM04S0A0S10NFD的Datasheet PDF文件第11页  
DESIGN CONSIDERATIONS (CON.)
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the module. An
input capacitance must be placed close to the modules
input pins to filter ripple current and ensure module
stability in the presence of inductive traces that supply
the input voltage to the module.
FEATURES DESCRIPTIONS
Remote On/Off
The DNL series power modules have an On/Off pin for
remote On/Off operation. Both positive and negative
On/Off logic options are available in the DNL series
power modules.
For positive logic module, connect an open collector
(NPN) transistor or open drain (N channel) MOSFET
between the On/Off pin and the GND pin (see figure 21).
Positive logic On/Off signal turns the module ON during
the logic high and turns the module OFF during the logic
low. When the positive On/Off function is not used, leave
the pin floating or tie to Vin (module will be On).
For negative logic module, the On/Off pin is pulled high
with an external pull-up resistor (see figure 22) Negative
logic On/Off signal turns the module OFF during logic
high and turns the module ON during logic low. If the
negative On/Off function is not used, leave the pin
floating or tie to GND. (module will be On)
Vin
Safety Considerations
For safety-agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the
input must meet SELV requirements. The power module
has extra-low voltage (ELV) outputs when all inputs are
ELV.
The input to these units is to be provided with a
maximum 15A of glass type fast-acting fuse in the
ungrounded lead.
Vo
I
ON/OFF
On/Off
RL
GND
Figure 21:
Positive remote On/Off implementation
Vin
Rpull-up
I
ON/OFF
Vo
On/Off
RL
GND
Figure 22:
Negative remote On/Off implementation
Over-Current Protection
To provide protection in an output over load fault
condition, the unit is equipped with internal over-current
protection. When the over-current protection is
triggered, the unit enters hiccup mode. The units
operate normally once the fault condition is removed.
DS_DNL10SIP16_01262007