欢迎访问ic37.com |
会员登录 免费注册
发布采购

E48SR15004NRFA 参数 Datasheet PDF下载

E48SR15004NRFA图片预览
型号: E48SR15004NRFA
PDF下载: 下载PDF文件 查看货源
内容描述: 德尔福系列E48SR12006 , 72W 1/8砖DC / DC电源模块: , 12V / 6A出48V [Delphi Series E48SR12006, 72W Eighth Brick DC/DC Power Modules: 48V in, 12V/6A out]
分类和应用: 电源电路
文件页数/大小: 13 页 / 918 K
品牌: DELTA [ DELTA ELECTRONICS, INC. ]
 浏览型号E48SR15004NRFA的Datasheet PDF文件第2页浏览型号E48SR15004NRFA的Datasheet PDF文件第3页浏览型号E48SR15004NRFA的Datasheet PDF文件第4页浏览型号E48SR15004NRFA的Datasheet PDF文件第5页浏览型号E48SR15004NRFA的Datasheet PDF文件第7页浏览型号E48SR15004NRFA的Datasheet PDF文件第8页浏览型号E48SR15004NRFA的Datasheet PDF文件第9页浏览型号E48SR15004NRFA的Datasheet PDF文件第10页  
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few
µH,
we advise adding a 10µF to 100
µF
electrolytic
capacitor (ESR < 0.7
at 100 kHz) mounted close to the
input of the module to improve the stability.
The input source must be insulated from the ac
mains by reinforced or double insulation.
The input terminals of the module are not operator
accessible.
If the metal baseplate is grounded, one Vi pin and
one Vo pin shall also be grounded.
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
normal-blow fuse with 10A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate
in a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB
layout issues, please contact Delta’s technical support
team. An external input filter module is available for
easier EMC compliance design. Application notes to
assist designers in addressing these issues are pending
to release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and
IEC60950-1999, if the system in which the power module
is to be used must meet safety agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2 or
SELV. An additional evaluation is needed if the source
is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 60 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or
drying
are
especially
important
for
un-encapsulated and/or open frame type power
modules. For assistance on appropriate soldering and
cleaning procedures, please contact Delta’s technical
support team.
E48SR12006_03022007
6