TK12
CURRENT RATINGS
T
case
= 60˚C unless stated otherwise.
Symbol
I
T(AV)
I
T(RMS)
I
T
Parameter
Mean on-state current
RMS value
Continuous (direct) on-state current
Conditions
Half wave resistive load
-
-
Max.
104
163
139
Units
A
A
A
T
case
= 80˚C unless stated otherwise.
Symbol
I
T(AV)
I
T(RMS)
I
T
Parameter
Mean on-state current
RMS value
Continuous (direct) on-state current
Conditions
Half wave resistive load
-
-
Max.
75
120
100
Units
A
A
A
SURGE RATINGS
Symbol
I
TSM
I
2
t
I
TSM
I
2
t
Parameter
Surge (non-repetitive) on-state current
I
2
t for fusing
Surge (non-repetitive) on-state current
I
2
t for fusing
Conditions
10ms half sine; T
case
= 125
o
C
V
R
= 50% V
RRM
- 1/4 sine
10ms half sine; T
case
= 125
o
C
V
R
= 0
Max.
1.12
6.2 x 10
3
1.4
9.8 x 10
3
Units
kA
A
2
s
kA
A
2
s
THERMAL AND MECHANICAL DATA
Symbol
R
th(j-c)
R
th(c-h)
Parameter
Thermal resistance - junction to case
Thermal resistance - case to heatsink
dc
Mounting torque 15.0Nm
with mounting compound
On-state (conducting)
T
vj
Virtual junction temperature
Reverse (blocking)
T
stg
-
Storage temperature range
Mounting torque
-
–40
12.0
125
150
15.0
o
Conditions
Min.
-
-
-
Max.
0.24
0.08
125
Units
o
C/W
C/W
o
o
C
C
C
o
Nm
2/8