EM91401 SERIES  
TONE/PULSE SWITCHABLE DIALER WITH LCD INTERFACE  
AND DUAL-TONE MELODY GENERATOR  
FUNCTION DESCRIPTIONS  
Dialing signal selection  
The EM91401 series incorporated a special keyboard scanning function that is connecting a resistor (typically  
is 560 Kohms) on keyboard scan pin to select many telephone specifications. The specifications are described  
as following :  
a. Mode  
ROW1  
R-Vdd  
NR  
b. M/B ratio  
ROW2  
NR  
Mode  
20 PPS  
Tone  
MBR (%)  
40:60  
R-Vss  
33:66  
R-Vss  
c. Flash time  
ROW3  
NR  
10 PPS  
d. Lock control method  
ROW4  
NR  
Tf (ms)  
600  
COL1  
R-Vdd  
NR  
Control method  
key lock  
none lock  
NR  
R-Vss  
NR  
100  
R-Vss  
R-Vss  
80  
R-Vss  
password lock  
R-Vss  
300  
e. Lock number  
COL2  
NR  
COL3  
Lock number  
NR  
R-Vss  
NR  
none  
0
NR  
R-Vss  
R-Vss  
9
R-Vss  
0.9  
Normal dialing  
Directly keying digital key on keyboard which number can be dialing output and stored in LNB memory  
automatically. Operating procedure described as follow :  
• To select Pulse or Tone mode.  
• Off-hook or turn on HF function.  
• Keying d1, d2, .. , dn. The “d” expressed digital keypad that included 1~9, *, 0, #, P, and PT keys. The “n”  
expressed unlimited.  
• The numbers d1, d2, .. , dn will be dialed out in Pulse or Tone mode as selection.  
LNB redial memory  
Storing:  
In normal dialing mode, every digital key was entry which number will be stored in LNB memory  
automatically. If entry digits are more than 32 digits, the redial function of LNB memory will be disabled.  
Otherwise, these numbers stored in LNB memory can be redial output.  
* This specification are subject to be changed without notice.  
10.1.1997  