欢迎访问ic37.com |
会员登录 免费注册
发布采购

1615A 参数 Datasheet PDF下载

1615A图片预览
型号: 1615A
PDF下载: 下载PDF文件 查看货源
内容描述: 1615A 1310纳米DFB激光器模块 [1615A 1310 nm DFB Laser Module]
分类和应用:
文件页数/大小: 4 页 / 648 K
品牌: EMCORE [ EMCORE CORPORATION ]
 浏览型号1615A的Datasheet PDF文件第1页浏览型号1615A的Datasheet PDF文件第3页浏览型号1615A的Datasheet PDF文件第4页  
1615A 1310 nm DFB Laser Module  
DATASHEET | JULY 2013  
FIBER OPTICS  
Electrical/Optical Characteristics  
Laser Temperature (TL) = 25°C, IF = IOP, Beginning of Life (BOL)  
Parameter  
Symbol  
Condition  
Min  
1300  
0.3  
30  
40  
35  
-
Typ  
Max  
Unit  
nm  
Wavelength  
-
-
-
1320  
Slope Efficiency  
Iop=Ith+40mA  
-
-
mW/mA  
dB  
ƞ
ISO  
Optical Isolation  
-
-
-
Optical Return Loss  
Side Mode Suppression Ratio  
Threshold Current  
Operating Current  
Monitor PD Responsivity  
Thermistor Resistance  
Thermistor Temp. Coefficient  
TEC Current  
ORL  
SMSR  
ITH  
Tc  
-
-
-
dB  
-
-
-
dB  
-
20  
120  
200  
10.5  
-
mA  
IOP  
-
-
-
mA  
rPD  
VRM=5V  
10  
9.5  
-
-
μA/mW  
KOhm  
%/C  
A
RTH  
TCTH  
ITEC  
-
10  
-4.4  
-
TOP = 25 C  
TOP = 25 C  
-1.5  
1.0  
-
1.6  
-
-40<TC<+85C, IF = 100 mA  
Fiber Length  
-
-
-
1.5  
900  
9/125  
m
Fiber Buffer  
-
-
m  
Fiber Core / Cladding  
-
-
-
m  
RF Characteristic  
Parameter  
Symbol  
Condition  
Min  
Typ  
Max  
Unit  
Frequency Range  
F
-
5
-
-
2700  
±2  
MHz  
5 MHz to 2700 MHz  
IF = Ith+40mA mA, TOP = 25C  
900 MHz  
(f1 = 942 MHz, f2 = 943 MHz)  
OMI = 5% per carrier (i)  
1800 MHz  
(f1 = 943 MHz, f2 = 1885 MHz)  
OMI = 5% per carrier (i)  
900 MHz  
(f1 = 942 MHz, f2 = 943 MHz)  
OMI = 5% per carrier (i)  
1800 MHz  
(f1 = 1842 MHz, f2 = 1843 MHz)  
OMI = 5% per carrier (i)  
2100 MHz  
(f1 = 2140 MHz, f2 = 2145 MHz)  
OMI = 5% per carrier (i)  
2600 MHz  
Frequency Response  
2nd Order IMD  
S21  
-
-
dB  
IMD2  
-
-
-
-
-
-62  
-64  
-80  
-78  
-72  
dBc  
-
-
-
-
dBc  
dBc  
dBc  
dBc  
3rd Order IMD  
IMD3  
(f1 = 2640 MHz, f2 = 2650 MHz)  
-
-
-
-70  
-
dBc  
OMI = 5% per carrier (i)  
Relative Intensity Noise  
RIN  
-
<-155  
dB/Hz  
(i) Test conditions: Iop = Ith+40 mA, Temp = 25°C, Fiber Length = 2 km  
In order to prevent reflection-induced distortion, the laser must be connected to an optical cable having a return  
loss of at least 55 dB for discrete reflections and 30 dB for distributed reflections.  
|
REV 2013.07  
Information contained herein is deemed reliable and accurate as of the issue date. EMCORE reserves the right to change the design or specification at any time without notice.