欢迎访问ic37.com |
会员登录 免费注册
发布采购

HPS35L-NNR-000 参数 Datasheet PDF下载

HPS35L-NNR-000图片预览
型号: HPS35L-NNR-000
PDF下载: 下载PDF文件 查看货源
内容描述: 有源功率因数校正 [Active Power Factor Correction]
分类和应用: 功率因数校正
文件页数/大小: 4 页 / 833 K
品牌: EMERSON-NETWORKPOWER [ EMERSON NETWORK POWER ]
 浏览型号HPS35L-NNR-000的Datasheet PDF文件第2页浏览型号HPS35L-NNR-000的Datasheet PDF文件第3页浏览型号HPS35L-NNR-000的Datasheet PDF文件第4页  
Embedded Power for
Business-Critical Continuity
HPS35 Series
350 - 1400 Watts
Total Power:
Input Voltage:
# of Outputs:
350 Watts
per module
90-264 VAC
Single and
standby
Rev. 2.18.09_133
HPS35 Series
1 of 4
Electrical Specifications
Input
Input voltage:
Frequency:
Inrush current:
Efficiency:
90-264 VAC typical
47-440 Hz
40 A peak typical @ 25 °C
80% typ @ full load, 230 VAC
0.98 typical @ 115 VAC, full load
AC ON -2 sec., Inhibit / Enable 160 ms
CISPR 22, EN55022 Level “B”
CISPR 22, EN55022 Level “B”
20 ms minimum (independent of input VAC)
5 ms early warning minimum before outputs lose regulation
Meets EN61000-3-2
Meets EN60950
±5% of nominal output voltage
±3%
1% of Vout pk - pk (20 MHz bandwidth)
4% from 25% to 75% load step
To within 1% in <300 µsec
115 - 130% of rated output current
Protected for continuous short circuit. Auto recovery.
120 - 140% AC Reset.
Main and Aux disabled when internal temp exceeds
safe operating range
Up to 0.5 V total drop
Current share to within 10% of total rated current on
main output
±5% of nominal
Special Features
• Active Power Factor Correction
• EN61000-3-2 compliant
• CISPR22, EN55022 Level-B
conducted/radiated EMI
• EN61000 immunity standards
• 5V
sb
@2A
• Overvoltage protection (OVP)
• Overcurrent protection (OCP)
• Overtemperature protection
(OTP)
• AC OK signal and indicator LED
• DC OK signal and indicator LED
• Remote Inhibit
• Remote Sense on main output
• Hot Plug
• N+1 Redundant
• 2 year warranty
Power factor:
Turn-on time:
EMI filter standard:
Radiated EMI:
Holdup time:
AC OK:
Harmonic distortion:
Isolation:
Leakage current standard: <0.5 mA max @ 230 VAC @ 60Hz (per module)
Output
Adjustability:
Overall regulation:
Ripple:
Dynamic response:
Recovery time:
Overcurrent protection:
Short circuit protection:
Overvoltage protection:
Thermal protection:
Reverse voltage protection: 100% of rated output voltage
Safety
• UL
• CSA
• TUV
• CB
• CE
UL60950-1, 1st Ed.
(April 1, 2003)
CSA C22.2 60950-1-03
EN60950-1:2001
(1st Ed.)
IEC60950-1,
1st Ed. (2001)
Mark (LVD)
Remote sense:
Single wire parallel:
DC OK: