40 Watts Medical
Total Power:
Input Voltage:
# of Outputs:
40-55 Watts
85-264 VAC
120-300 VDC
Single
Rev. 9.8.09_28
LPS40-M Series
 of 3
Electrical Specifications
Special Features
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI filter:
Safety ground
leakage current:
85 - 264 VAC; 120 - 300 VDC
47 - 440 Hz
< 18A peak @ 115 VAC; <36A peak @ 230 VAC, cold start @ 25 °C
1A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted; CISPR 22 Class A conducted;
EN55022 Class A conducted; VDE 0878 PT3 Class A conducted
< 75µA @ 50/60 Hz, 264 VAC input
Medical safety approvals
Universal input
3” x 5” footprint
Less than 1U high
Remote sense on main output
Low output ripple
Adjustable 5V output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX40 enclosure kit available
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
40 W for convection; 55 W with 30CFM forced air
-5, +10% minimum
20ms @ 40 W load, 115 VAC nominal line
Safety
• VDE
0750/EN60601-1
(IEC601)
• UL
UL2601 E182560
• CSA
CSA 22.2 No.601.1
LR109492
• CE Mark (LVD)
Short circuit protection on all outputs
Case overload protected @ 110 - 145% above peak rating
Overvoltage protection: 5V output; 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal
output
Remote sense:
Compensates for 0.5 V lead drop minimum.
Will operate without remote sense connected.
Reverse connection protected.