欢迎访问ic37.com |
会员登录 免费注册
发布采购

LPS64-M 参数 Datasheet PDF下载

LPS64-M图片预览
型号: LPS64-M
PDF下载: 下载PDF文件 查看货源
内容描述: 医疗安全认证 [Medical safety approvals]
分类和应用: 医疗
文件页数/大小: 3 页 / 122 K
品牌: EMERSON-NETWORKPOWER [ EMERSON NETWORK POWER ]
 浏览型号LPS64-M的Datasheet PDF文件第2页浏览型号LPS64-M的Datasheet PDF文件第3页  
Embedded Power for
Business-Critical Continuity
LPS60-M Series
60 Watts
Medical
Total Power:
Input Voltage:
# of Outputs:
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Single
Rev. 07.23.07
LPS60-M Series
1 of 3
RoHS
Electrical Specifications
Special Features
Medical safety approvals
Universal input
3" x 5" footprint
Remote sense
Built in EMI filter
Low output ripple
Adjustable output voltage
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground leakage
current
85 - 264 VAC (wide range)
120 - 300VDC
47-440 Hz
<18A peak @ 115VAC, <36A peak @230 VAC,
cold start @ 25°C
1.5A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class A conducted; CISPR22 Class A conducted;
EN55022 Class A conducted; VDE0878 PT3 Class A conducted
<75μA @ 50/60Hz; 264VAC input
Output
Maximum power
Adjustment range
Hold-up time
Overload protection
60W for convection; 80W with 30CFM forced air
-5, +10% minimum
20ms @ 60W load, 115VAC nominal line
Safety
VDE
UL
CSA
CE
0750/EN60950 (IEC601)
21310-3336-0015
UL2601
E182560
CSA 22.2 No.601.1
LR109492
Mark (LVD)
Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5V output; 5.7 - 6.7VDC. Other outputs 10% to 25%
above nominal output
Remote sense
Compensates for 0.5V lead drop min. Will operate without
remote sense connected. Reverse connection protected.