Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
-40° to 85°C
±.04% per °C
>550,000 hours at full load and 25°C ambient conditions
Rev. 06.15.07
LPT60-M Series
2 of 3
Storage temperature:
Temperature coefficient:
MTBF demonstrated:
Ordering Information
Maximum Load
Maximum Load
with Convnection
with 30CFM
cooling
Forced Air
LPT62-M
+5V
0.7A
7A
8A
+12V
0.3A
3A
3.5A
-12V
0A
0.7A
1A
LPT63-M
+5V
0.7A
7A
8A
+15V
0.3A
2.8A
3.3A
-15V
0A
0.7A
1A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
Model
Number
Output
Voltage
Minimum
Load
Peak Load
1
10A
6A
1.5A
10A
4A
1.5A
Regulation
2
±2%
±5%
±5%
±2%
±5%
±5%
Ripple P/P (PARD)
3
50mV
120mV
120mV
50mV
150mV
150mV
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.