NLP40-7615J图片预览
型号: NLP40-7615J
PDF下载: 下载PDF文件 查看货源
内容描述: 40-50 W AC / DC通用输入开关电源 [40-50 W AC/DC Universal Input Switch Mode Power Supplies]
分类和应用: 开关
文件页数/大小: 3 页 / 91 K
品牌: EMERSON-NETWORKPOWER [ EMERSON NETWORK POWER ]
 浏览型号NLP40-7615J的Datasheet PDF文件第1页浏览型号NLP40-7615J的Datasheet PDF文件第3页  
NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT
VOLTAGE
+3.3 V (I
A
)
+12 V (I
B
)
–12 V (I
C
)
+5 V (I
A
)
+12 V (I
B
)
–12 V (I
C
)
+5 V (I
A
)
+15 V (I
B
)
–15 V (I
C
)
+12 V (I
A
)
-12 V (I
B
)
+5 V (I
A
)
+12 V (I
B
)
3.3 V (I
A
)
5V
12 V
15 V
24 V
48 V
Notes
1
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
RIPPLE
MAX
4A
2A
0.2 A
4A
2A
0.2 A
4A
1.6 A
0.2 A
1.8 A
1.8 A
4A
2A
8A
8A
3.3 A
2.6 A
1.6 A
0.8 A
(1)
(3)
TOTAL
REGULATION
MODEL NUMBER
NLP40-76T366J
(11,12)
PEAK
5A
3A
1A
5A
3A
1A
5A
2A
1A
(2)
FAN
(1)
4.5 A
3A
0.5 A
4.5 A
3A
0.5 A
4.5 A
2A
0.5 A
2.1 A
2.1 A
4.5 A
3A
9A
9A
4A
3.3 A
2A
1A
50 mV
120 mV
120 mV
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
120 mV
120 mV
50 mV
120 mV
50 mV
50 mV
120 mV
150 mV
240 mV
300 mV
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
(5)
NLP40-7608J
(5)
NLP40-7610J
(5)
2.2 A
2.2 A
5A
3A
10 A
10 A
4.5 A
3.6 A
2.5 A
1.1 A
NLP40-7627J
(5)
NLP40-7629J
(5)
NLP40-76S3J
NLP40-7605J
NLP40-7612J
NLP40-7615J
NLP40-7624J
NLP40-7617J
Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
2
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
3
Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
4
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
5
For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
0.25 ≤ I
A
/ I
B
≤ 5, for I
B
> 0.3 A
0.50 ≤ I
A
/ I
B
≤ 5, for I
B
< 0.3 A
For maximum output current I(C) on triple output models, i.e. for
I
C
= IMax., I
A
min. ≥ 0.5 A and I
A
≥ I
B
.
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ I
A
/ I
B
≤ 2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ I
A
/ I
B
≤ 4.
6
For optimum reliability, no part of the heatsink should exceed 120
°
C, and
no semiconductor case temperature should exceed 130
°
C.
7
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
8
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9
When the input voltage is <90 Vac the operating range is 0
°
C to +40
°
C.
10
For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
NATURAL
CONVECTION
COOLING
25W
20W
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
File Name: nlp40.pdf Rev (03): 08 Nov 2005