Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
EMC Charateristics
(11, 12)
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-2, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac, 65 W
Input/output
Input/chassis
Fixed
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 2
16 ms @ 65 W
78 ms @ 65 W
72% typical
3000 Vac
1500 Vac
100 kHz, ±5 kHz
Rev.06.02.08
NLP65 Series
2 of 4
General Specifications
Hold-up time
Efficiency
Isolation voltage
Switching frequency
Approvals and standards EN60950, VDE0805
(see Notes 9, 13)
IEC950, UL1950, CCC60950
CSA C22.2 No. 950
Weight
MTBF demonstrated
283 g (10 oz)
MIL-HDBK-217F
150,000 hours min
Environmental Specifications
Thermal performance
(see Notes 1, 3, 10)
Operating ambient,
0 °C to +70 °C
(See derating curve)
Non-operating
-40 °C to +85 °C
50 °C to 70 °C ambient,
Derate to
convection cooled
50% load
0 °C to 50 °C, ambient,
65 W
convection cooled
0 °C to 50 °C ambient,
75 W
20 CFM forced air (See Note 10)
Peak (0 °C to +50 °C, 60 s) See table
Non-condensing
Operating
Non-operating
5-500 Hz
per MIL-STD-810E
5% to 95% RH
10,000 feet max
30,000 feet max
2.4 G rms peak
516.4 Part IV
DERATING CURVE
Output Power (Watts)
75W
20 CFM FORCED AIR COOLING
65W
NATURAL
CONVECTION
COOLING
38W
32W
Relative humidity
Altitude
Vibration (see Note 5)
Shock
0°C
10°C 20°C 30°C 40°C 50°C 60°C 70°C