EM6603
14 Metal Mask Options
The following options can be selected at the time of programming the metal mask ROM.
Table 40 Input/Output Ports
Pull-Up
Yes
/
No
Pull-Down
Yes
/
No
Nch-open drain
Yes
/
No
Input blocked when
Output
Yes
/
No
Output Hi-Z in
SLEEP mode
Yes
/
No
0
1
4
5
*
1
6
*
2
A0
A1
A2
A3
B0
B1
B2
B3
C0
C1
C2
C3
D0
D1
D2
D3
PA0 input
PA1 input
PA2 input
PA3 input
PB0 In/Out
PB1 In/Out
PB2 In/Out
PB3 In/Out
PC0 In/Out
PC1 In/Out
PC2 In/Out
PC3 In/Out
PD0 In/Out
PD1 In/Out
PD2 In/Out
PD3 In/Out
Put one letter (Y, N, R, F)in each BOX from proposed for the column.
*1
Port wise for PortC and PortD (one possibility for the whole port); PortB bit-wise
*2
Port-wise for PortC and PortD (one possibility for the whole port); PortB bit-wise
Table 41 PortA RESET option
- One Option must be selected
NO PortA reset
combination
PA0 & PA1 logic AND
input reset
PA0 & PA1 & PA2 logic
AND input reset
PA0 & PA1 & PA2 & PA3
logic AND input reset
0
1
2
3
RA
PortA RESET
Table 42 SVLD levels
– See 16.6 DC characteristics –SV Detector Levels – Write typ. value of used levels
typ.
VL1
level [V]
VL
SVLD level in Volts
typ.
VL2
level [V]
typ.
VL3
level [V]
Software name is :
______________.bin,
dated
______________
The customer should specify the required options at the time of ordering.
A copy of this sheet, as well as the « Software ROM characteristic file » generated by
the assembler (*.STA) should be attached to the order.
03/02 REV. G/439
Copyright
2002, EM Microelectronic-Marin SA
27