EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323 / USA/ USA
1-800-383-7323
1-800-383-7323 / CANADA
1-800-383-7323 / CANADA
+ 44 (0) 208 920 2306 / EUROPE
ENERGIZER NO. A76
Chemical System:
Manganese Dioxide (Mn0
2
)
Industry Standard Dimensions in mm (inches)
Designation:
Battery Voltage:
Average Weight:
Volume:
Average Capacity:
ANSI / NEDA-1166A, IEC - LR48
1.5 Volts
2.3 grams (0.08 oz.)
0.50 cubic centimeters (0.03 cubic inch)
150 mAh to 0.9 volts
(Rated at 7.5k ohms continuous at 21ºC)
TYPICAL DISCHARGE CURVE
Simulated Test @ 21ºC (70ºF)
1.6
Closed Circuit Voltage
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
DESIGNED FOR ELECTRONIC APPLICATIONS
WHICH MAY REQUIRE HIGH RATE PULSES
0
150
300
450
600
750
900
Service, Hours
Simulated Application Test
Estimated Average Service at 21ºC (70ºF)
Typical Drains
at 1.25V
(microamperes)
0.17
Cutoff Voltage
Load
(ohms)
7,500
0.9V
900 Hours
Schedule:
24 hours/day
BULGE DATA:
This battery will bulge as it is discharged but will not exceed the
maximum height shown on the battery drawing.
INTERNAL RESISTANCE:
Typical closed circuit voltage during discharge on a load of 100 ohms
for 0.10 to 2.0 seconds.
Depth of Discharge as Percent of Rated Capacity
Temperature
21ºC (70ºF)
0%
1.55V
40%
1.29V
80%
1.10V
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
Form No. EBC - 4407D