欢迎访问ic37.com |
会员登录 免费注册
发布采购

EN5322QI-E 参数 Datasheet PDF下载

EN5322QI-E图片预览
型号: EN5322QI-E
PDF下载: 下载PDF文件 查看货源
内容描述: 2电压模式同步降压PWM DC -DC转换器集成电感器 [2 A Voltage Mode Synchronous Buck PWM DC-DC Converter with Integrated Inductor]
分类和应用: 转换器电感器
文件页数/大小: 16 页 / 324 K
品牌: ENPIRION [ ENPIRION, INC. ]
 浏览型号EN5322QI-E的Datasheet PDF文件第1页浏览型号EN5322QI-E的Datasheet PDF文件第3页浏览型号EN5322QI-E的Datasheet PDF文件第4页浏览型号EN5322QI-E的Datasheet PDF文件第5页浏览型号EN5322QI-E的Datasheet PDF文件第6页浏览型号EN5322QI-E的Datasheet PDF文件第7页浏览型号EN5322QI-E的Datasheet PDF文件第8页浏览型号EN5322QI-E的Datasheet PDF文件第9页  
EN5322QI
Absolute Maximum Ratings
CAUTION:
Absolute maximum ratings are stress ratings only. Functional operation beyond recommended operating
conditions is not implied. Stress beyond absolute maximum ratings may cause permanent damage to the device.
Exposure to absolute maximum rated conditions for extended periods may affect device reliability.
Absolute Maximum Electrical Ratings
Voltages on: PVIN, AVIN, VOUT
Voltages on: VSENSE, VS0, VS1, VS2, ENABLE, POK
Voltage on: VFB
ESD Rating (Human Body Model)
ESD Rating (Charge Device Model)
-0.3 V
-0.3 V
-0.3 V
2 kV
500 V
-40 °C
-65 °C
MIN
6.5 V
V
IN
2.7 V
MAX
Absolute Maximum Thermal Ratings
Ambient Operating Range
Storage Temperature Range
Reflow Peak Body Temperature MSL3 (10 s)
+85 °C
+150 °C
+260 °C
Thermal Characteristics
TYP
MAX
Thermal Shutdown
T
SD
155
Thermal Shutdown Hysteresis
T
SDH
15
Thermal Resistance: Junction to Case (0 LFM)
6
θ
JC
Thermal Resistance: Junction to Ambient (0 LFM)*
36
θ
JA
* Based on a 2 oz. copper board and proper thermal design in line with JEDEC EIJ-JESD51 standards
PARAMETER
SYMBOL
MIN
UNITS
°C
°C
°C/W
°C/W
Recommended Operating Conditions
SYMBOL
MIN
Input Voltage Range
V
IN
2.4
Output Voltage Range
V
OUT
0.6
Output Current
I
LOAD
0
Operating Junction Temperature
T
J
-45
Note: V
DROPOUT
is defined as (I
LOAD
x Dropout Resistance) including temperature effect.
PARAMETER
V
IN
MAX
5.5
- V
DROPOUT
2
+125
UNITS
V
V
A
°C
Electrical Characteristics
V
IN
= 5 V and T
A
= 25 °C, unless otherwise noted.
PARAMETER
Operating Input Voltage
Under Voltage Lockout
UVLO Hysteresis
Output Voltage with VID
Codes (Note 1)
SYMBOL
TEST CONDITIONS
V
IN
going low to high
T
A
= 25 °C; V
IN
= 5V
I
LOAD
= 100 mA
VS2 VS1 VS0 VOUT (V)
0
0
0
3.3
0
0
1
2.5
0
1
0
1.8
0
1
1
1.5
1
0
0
1.25
1
0
1
1.2
1
1
0
0.8
T
A
= 25 °C; V
IN
= 5V
V
IN
V
UVLO
MIN
2.4
TYP
2.2
0.15
MAX
5.5
UNITS
V
V
V
V
OUT
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
-2.0
0.588
0.600
+2.0
+2.0
+2.0
+2.0
+2.0
+2.0
+2.0
0.612
%
VFB Voltage
V
FB
V
©Enpirion
2008 all rights reserved, E&OE
03454
2
4/24/2009
www.enpirion.com