ELD-760-524 参数 Datasheet PDF下载

ELD-760-524图片预览
型号: ELD-760-524
PDF下载: 下载PDF文件 查看货源
内容描述: LED - 灯 [LED - Lamp]
分类和应用:
文件页数/大小: 1 页 / 92 K
品牌: EPIGAP [ EPIGAP OPTOELECTRONIC GMBH ]
   
LED - Lamp
15.11.2007
Radiation
Infrared
Type
DDH
Technology
AlGaAs/AlGaAs
ELD-760-524
rev. 02
Case
5 mm plastic lens
Description
High-power, high-speed LED with narrow beam
angle and high reliability, housing with standoff
leads
12,35
Anode
1
1
1
2,75
0,5
Note: Special packages without standoff available on request
Cathode
2
1,5
2
0,5
1
8,6
Applications
Ø5
Ø5,75
36,5
-1,0
+1,0
Optical communications, safety equipment,
automation
Maximum Ratings
T
amb
= 25°C, unless otherwise specified
Parameter
Forward current (DC)
Peak forward current
Power dissipation
Operating temperature range
Storage temperature range
Junction temperature
Lead soldering temperature
< 5s, 3.0 mm from case
(t
P
50 µs, t
P
/T = 1/2)
Test
сonditions
Symbol
I
F
I
FM
P
D
T
amb
T
stg
T
J
T
sol
Value
50
100
120
-20 to +85
-55 to +100
100
260
Unit
mA
mA
mW
°C
°C
°C
°C
Optical and Electrical Characteristics
T
amb
= 25°C, unless otherwise specified
Test
Parameter
conditions
I
F
= 20 mA
Forward voltage
Forward voltage
1
Reverse voltage
Radiant power
Radiant power
1
Radiant intensity
Radiant intensity
1
Peak wavelength
Spectral bandwidth at 50%
Viewing angle
Switching time
1
Symbol
V
F
V
F
V
R
Φ
e
Φ
e
Ι
e
Ι
e
λ
p
∆λ
0.5
ϕ
t
r,
t
f
Min
Typ
Max
Unit
V
V
V
mW
mW
mW/sr
mW/sr
1.7
2.0
5
4
24
2.0
I
F
= 50 mA
I
R
= 100 µA
I
F
= 20 mA
I
F
= 50 mA
I
F
= 20 mA
I
F
= 50 mA
I
F
= 20 mA
I
F
= 20 mA
I
F
= 20 mA
I
F
= 20 mA
6
14
30
70
750
760
30
20
35
775
nm
nm
deg.
ns
for information only
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer.
EPIGAP
Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201
1 of 1
Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545
Note: All measurements carried out on
EPIGAP
equipment