欢迎访问ic37.com |
会员登录 免费注册
发布采购

S2R72A43F07E2 参数 Datasheet PDF下载

S2R72A43F07E2图片预览
型号: S2R72A43F07E2
PDF下载: 下载PDF文件 查看货源
内容描述: 宽温度范围低功耗 [Wide temperature range Low power consumption]
分类和应用:
文件页数/大小: 32 页 / 330 K
品牌: EPSON [ EPSON COMPANY ]
 浏览型号S2R72A43F07E2的Datasheet PDF文件第8页浏览型号S2R72A43F07E2的Datasheet PDF文件第9页浏览型号S2R72A43F07E2的Datasheet PDF文件第10页浏览型号S2R72A43F07E2的Datasheet PDF文件第11页浏览型号S2R72A43F07E2的Datasheet PDF文件第13页浏览型号S2R72A43F07E2的Datasheet PDF文件第14页浏览型号S2R72A43F07E2的Datasheet PDF文件第15页浏览型号S2R72A43F07E2的Datasheet PDF文件第16页  
5. Pin Function and Description  
USB (S2R72A42)  
Pin No.  
18  
Name  
I/O  
RESET  
Description  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
Not used (leave open)  
17  
21  
20  
27  
34  
28  
35  
POWER (applies to S2R72A44/A43/A42)  
Pin No.  
Name  
HVDD  
Voltage  
3.3 V  
1.8  
Description  
4, 9, 15, 31, 42  
3.3 V supply for USB and IO  
1.8 V supply for internal core  
GND  
3, 8, 16, 29, 43, 46  
6, 11, 19, 30, 40, 48  
LVDD  
VSS  
0 V  
5.1 VBUS switch management  
Dx{x=1-4}_VBUSEN pins corresponding to each down ports are surved for this purpose.  
VBUS switch devices connected to those pins can be managed individually (Individual mode, i.e. MODE2 =  
High) or concurrently (Gang mode, i.e. MODE2 = Low).  
Assertion of VBUSEN signals are caused only by SetPortFeature(PORT_POWER) standard request which is  
issued by the Host. Further conditions as listed below are required for VBUSEN signals to be asserted at that  
moment.  
- MODE1 pin is set to High (i.e. bPwrOn2PwrGood = 0b1)  
- The LSI is under configured condition (as USB standard meaning) as a result of receiving SetConfiguration()  
standard request from the Host.  
- Dx{x=1-4}_VBUSFLG pins correspoinding to each of down ports are not forced to low.  
If each of those VBUSFLG signals is asserted, PORT_OVER_CURRENT status on each down port is set.  
Those statuses can be checked with GetPortStatus() standard request which is issued repeatedly by ordinaly host  
stacks.  
Lack of at least one of above conditions causes nagation of VBUSEN signal. Once VBUSEN is negated, it is not  
asserted again without reception of SetPortFeature(PORT_POWER) even if conditions are returned in order.  
In Gang mode, D1_VBUSEN alone is served for the VBUS management function.  
Please refer to the USB 2.0 standard for USB defined things such as bPwrOn2PwrGood condition, standard  
requests, Individual mode or Gang mode.  
S2R72A4x Series Data Sheet  
(Rev.1.20)  
Seiko Epson Corporation  
9