PT28-21B/TR8
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item
Test Conditions
Test Hours/ Sample
Cycles
Sizes
6Mins
22pcs
22pcs
I
C(ON)
≦L×0.8
22pcs
L:Lower
Specification
Limit
22pcs
22pcs
22pcs
22pcs
0/1
0/1
0/1
0/1
0/1
Failure
Judgement
Criteria
Ac/Re
1 REFLOW
TEMP.:260℃±5℃
0/1
0/1
5secs
2 Temperature Cycle H : +100℃
L : -40℃
3 Thermal Shock
H :+100℃
L :-10℃
4 High Temperature
Storage
5 Low Temperature
Storage
15mins 50Cycles
5mins
15mins
5mins 50Cycles
10secs
5mins
1000hrs
1000hrs
1000hrs
1000hrs
TEMP.:+100℃
TEMP.:-40
6 DC Operating Life V
CE
=5V
7 High Temperature/ 85℃ / 85% R.H
High Humidity
Everlight Electronics Co., Ltd.
Device No:DTT-028-019
http:\\www.everlight.com
Prepared date:07-20-2005
Rev 2
Page: 8 of 10
Prepared by:Jaine Tsai