ITR8402-F-A
█
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO.
Item
Test Condition
Test Sample
Hours/
Size
Cycle
Failure
Judgement
Criteria
Ac/Re
1
Solder Heat
TEMP : 260℃ ± 5
℃
10sec
More than
90% of lead to
22 PCs be covered by
soldering
I
R
≧U×2
22 PCs Ee≦L×0.8
V
F
≧U×1.2
U :Upper
specification
limit
L :Lower
specification
limit
0/1
H : +100℃
15 mins
5 min
2
Temperature Cycle
L : -40℃
H : +100℃
300
cycle
0/1
15 min
5 min
3
Thermal Shock
L : -10℃
10 sec
5 min
300
cycle
22 PCs
0/1
4
5
6
7
High Temperature
TEMP. : +100℃
Storage
Low Temperature
TEMP. : -40℃
Storage
DC Operating Life
V
CE
=5V
I
F
=20mA
1000
hrs
1000
hrs
1000
hrs
1000
hrs
22 PCs
22 PCs
22 PCs
22 PCs
0/1
0/1
0/1
0/1
High Temperature /
85℃ / 85% R.H.
High Humidity
Everlight Electronics Co., Ltd.
Device No: DRX-0000001
http://www.everlight.com
Prepared date:2008/10/22
Rev: 2
Page: 6 of 7
Prepared by:else zhuang