欢迎访问ic37.com |
会员登录 免费注册
发布采购

SP3496EEN-L 参数 Datasheet PDF下载

SP3496EEN-L图片预览
型号: SP3496EEN-L
PDF下载: 下载PDF文件 查看货源
内容描述: 高速+ 3.3V的RS - 485 / RS - 422收发器,带有+/- 15KV ESD保护和高级故障保护 [HIGH SPEED +3.3V RS-485/RS-422 TRANSCEIVERS WITH +/-15KV ESD PROTECTION AND ADVANCED FAILSAFE]
分类和应用: 线路驱动器或接收器驱动程序和接口接口集成电路光电二极管
文件页数/大小: 17 页 / 480 K
品牌: EXAR [ EXAR CORPORATION ]
 浏览型号SP3496EEN-L的Datasheet PDF文件第2页浏览型号SP3496EEN-L的Datasheet PDF文件第3页浏览型号SP3496EEN-L的Datasheet PDF文件第4页浏览型号SP3496EEN-L的Datasheet PDF文件第5页浏览型号SP3496EEN-L的Datasheet PDF文件第6页浏览型号SP3496EEN-L的Datasheet PDF文件第7页浏览型号SP3496EEN-L的Datasheet PDF文件第8页浏览型号SP3496EEN-L的Datasheet PDF文件第9页  
SP3495E-3497E
HIGH SPEED +3.3V RS-485/RS-422 TRANSCEIVERS WITH +/-15KV ESD PROTECTION AND
ADVANCED FAILSAFE
MAY 2009
REV. 1.0.0
GENERAL DESCRIPTION
The
SP3495E - SP3497E
transceivers are suitable
for high speed bidirectional communication on
multipoint bus transmission lines. They are designed
for balanced data transmission and comply with both
RS-485 and RS-422 EIA standards. Each device
contains one differential driver and one differential
receiver
Driver differential outputs and receiver differential
inputs are connected internally to form a half-duplex
input/output to the RS-485 bus. Separate RE and DE
pins enable and disable the driver and receiver
independently or may be externally connected
together as a direct control. The device enters a low
power shutdown mode if both driver and receiver are
disabled. the bus-pin outputs of disabled or powered
down devices are in high impedance state. The high
impedance driver output is maintained over the entire
common-mode voltage range of -7V to +12V.
SP3495E - SP3497E operates from a single 3.3V
power supply. SP3495E - SP3497E transceivers load
the data bus only half as much as a standard RS-485
unit load. This allows up to 64 devices to be
connected simultaneously on a bus without violating
required RS-485 signal margin and without using
repeaters. Excessive power dissipation caused by
bus contention or by shorting outputs to ground or a
voltage source is prevented by short circuit protection
and thermal shutdown. This feature forces the driver
output into high impedance state if the absolute value
of the output current exceeds 250mA or if junction
temperature exceeds 165°C. Receivers will fail-safe
to a logic high output state if the inputs are
unconnected (floating) or shorted. All RS-485 inputs
F
IGURE
1. T
YPICAL
A
PPLICATION
C
IRCUIT
and outputs are ESD protected up to +/-15kV Human
Body Model.
FEATURES
3.3V Single Supply Operation
High Speed up to 32Mbps
Robust +/-15kV ESD protection
Hot Swap glitch protection
Advanced Fail-safe Receiver Inputs
Half Unit Load, 64 Transceivers on bus
Driver short circuit current limit and thermal
shutdown for overload protection
Low Current 1uA shutdown mode
TYPICAL APPLICATIONS
Factory Automation Controls
Motor Control
Industrial Process Control
Building Automation
Security Systems
Remote Utility Meter Reading
Long or un-terminated transmission lines
Exar
Corporation 48720 Kato Road, Fremont CA, 94538
(510) 668-7000
FAX (510) 668-7017
www.exar.com