100304
Industrial Version
PLCC DC Electrical Characteristics
(Note 4)
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND, T
C
= −40°C
to
+85°C
Symbol
V
OH
V
OL
V
OHC
V
OLC
V
IH
V
IL
I
IL
I
IH
Parameter
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage
Input LOW Current
Input HIGH Current
D
2a
–D
2e
D
1a
–D
1e
I
EE
Power Supply Current
−69
250
350
−30
−69
250
350
−30
mA
Inputs OPEN
µA
V
IN
=
V
IH (Max)
−1170
−1830
0.50
T
C
= −40°C
Min
−1085
−1830
−1095
−1565
−870
−1480
−1165
−1830
0.50
Max
−870
−1575
T
C
=
0°C to
+85°C
Min
−1025
−1830
−1035
−1610
−870
−1475
Max
−870
−1620
Units
mV
mV
mV
mV
µA
Conditions
V
IN
=V
IH (Max)
or V
IL (Min)
V
IN
=
V
IH(Min)
or V
IL (Max)
for All Inputs
Guaranteed LOW Signal
for All Inputs
V
IN
=
V
IL (Min)
Loading with
50Ω to
−2.0V
Loading with
50Ω to
−2.0V
Guaranteed HIGH Signal
Note 4:
The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
PLCC AC Electrical Characteristics
V
EE
= −
4.2V to
−
5.7V, V
CC
=
V
CCA
=
GND
Symbol
t
PLH
t
PHL
t
PLH
t
PHL
t
TLH
t
THL
Parameter
Propagation Delay
D
na
–D
ne
to O, O
Propagation Delay
Data to F
Transition Time
20% to 80%, 80% to 20%
T
C
=
40°C
Min
0.35
1.00
0.35
Max
1.55
2.40
1.10
T
C
= +25°C
Min
0.40
1.00
0.35
Max
1.45
2.40
1.15
T
C
= +85°C
Min
0.40
1.15
0.35
Max
1.55
3.00
1.10
Units
ns
Conditions
ns
ns
Figures 1, 2
3
www.fairchildsemi.com