欢迎访问ic37.com |
会员登录 免费注册
发布采购

1451 参数 Datasheet PDF下载

1451图片预览
型号: 1451
PDF下载: 下载PDF文件 查看货源
内容描述: 系统传感器电离烟雾探测器 [System Sensor Ionization Smoke Detector]
分类和应用: 传感器
文件页数/大小: 2 页 / 101 K
品牌: FCI-CONNECTOR [ FCI CONNECTOR ]
 浏览型号1451的Datasheet PDF文件第2页  
1451
System Sensor
Ionization Smoke Detector
Description
The System Sensor 1451 ionization type smoke detectors
are specifically designed to meet the performance require-
ments of fire detection/alarm systems. The 1451 ioniza-
tion detector uses a state-of-the-art, dual unipolar sensing
chamber. The detector is designed to provide open area
detection and when installed in a two-wire base is com-
patible with FCI fire alarm control panels. The detectors
operation and sensitivity can be tested in place.
The 1451 detector is of plug-in construction and plugs into
the same base as the 2451 Series photoelectronic smoke
detectors, making both models interchangeable. Bases
are available for two-wire, four-wire, and 120 VAC four-
wire operation.
Two visible LEDs on each detector flash approximately
every ten seconds indicating that power is being applied
to the detector. The LEDs light steadily when the detector
is in alarm. A remote LED annunciator is available as an
optional accessory.
The 1451 detector is Listed for use inside ducts up to a
velocity of 1,200 FPM.
Sensitivity testing is performed by placing a test magnet
against the cover. The LED on the detector should light
within 5 seconds.
Field metering of detector sensitivity may be performed
with the aid of a voltmeter and Test Kit, MOD 400R.
1451
Features
Unique dual unipolar sensor provides exceptional
stability.
Easy plug-in of the head to base.
Built-in tamper-resistant feature.
Built-in test switch.
Built-in visual alarm indicators.
360° view angle of alarm LEDs.
Compatible with FCI control panels.
Field adjustable sensitivity.
Field metering of detector sensitivity.
Removable insect screen and cover for field
cleaning.
Sealed against dirt, insects, and back pressure.
Insect-resistant screening (.020"/.508 mm
openings).
Specifications
Nominal Sensitivity
Operating voltage
Operating
temperature
Operating humidity
Air velocity
Altitude
Construction
Diameter
Height
Weight
1.5 %/ft
8.5 - 35 VDC (24 VDC nominal)
32° to 120° F (0° to 49° C)
10 % - 93 % relative humidity
1,200 FPM
10,000 ft.
Off-white flame retardant plastic
6.2 inches
(15.7 cm)
3.2 inches
(8.1 cm)
0.5 lb (277 g)
An ISO 9001-2000 Company
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2006 Gamewell-FCI. All rights reserved.
www.gamewell-fci.com
9020-0584 Rev. B page 1 of 2