FTR-1629-XX DWDM GBIC Preliminary Product Specification – June 2003
F i n i s a r
II. Electrical Power Interface
The GBIC specification calls for a range of 4.75V to 5.25 volts as described in Table 2.
The maximum voltage of 6V is not to be applied continuously.
Parameter
Symbol
Min
Typ
Max
Units Notes/Conditions
Supply Current
Inrush Current
Is
250
400
350
30
mA
mA
mA
Tc <= 70oC
Tc <= 65oC
<= 300 msec above steady
state current
Isurge
Vmax
Maximum Voltage
Input Voltage
6
V
V
V
cc
4.75
5.0
5.25
Referenced to GND
Table 2. Electrical Power Interface
III.
Low Speed Signals
RX_LOS, TX_DISABLE, and TX_FAULT are TTL signals as described in Table 3.
MOD_DEF(1) (SCL) and MOD_DEF(2) (SDA) are open drain CMOS signals (see
section XI, “Serial Communication Protocol”). Both MOD_DEF(1) and MOD_DEF(2)
must be pulled up to host_Vcc. For more detailed information, see sections 5.3.1 – 5.3.8
in the GBIC Specification Revision 5.51.
Parameter
Symbol
Min
Max
Units Notes/Conditions
GBIC Output LOW
VOL
0
0.5
V
4.7k to 10k pull-up to host_Vcc,
measured at host side of connector
GBIC Output HIGH
GBIC Input LOW
VOH
VIL
host_Vcc -
host_Vcc +
V
V
4.7k to 10k pull-up to host_Vcc,
measured at host side of connector
4.7k to 10k pull-up to Vcc,
measured at GBIC side of
connector
0.5
0
0.3
0.8
GBIC Input HIGH
VIH
2
Vcc + 0.3
V
4.7k to 10k pull-up to Vcc,
measured at GBIC side of
connector
Table 3. Low Speed Signals – Electronic Characteristics
Ó Finisar Corporation
PRELIMINARY and Confidential
Page 4