F75393
6.
If the distance to the remote sensor is more than 8 inches, the use of twisted pair cable is recommended. It will work up to
around 6 to 12 feet.
7.
Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance will affect the
measurement accuracy. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also
induce errors. 1
Ω
series resistance introduces about 0.5
℃
error.
7. Register Description
Configuration Register
Index 03h(Read),
Name
ALERT_MASK
RUN_STOP
Reserved
PWR_DON
R/W Default
R/W
R/W
RO
R/W
0
0
0
0
7.1
Bit
7
6
5-1
0
09h(Write)
Description
Set to 1, mask ALERT# signal output.
Set to 0, monitor. Set to 1, stop monitor (power down mode).
Reserved, always return 0.
Power down this device.
7.2
Bit
7
6
Status Register
Index 02h
Name
ADC_BUSY
VT1HIGH
R/W Default
RO
RO
0
0
Description
Set to 1, ADC is converting.
Set to 1, VT1 temperature exceeds high limit.
Set to 0, VT1 temperature does not exceed high limit.
5
VT1LOW
RO
0
Set to 1, VT1 temperature goes below low limit.
Set to 0, VT1 temperature does not goes below low limit.
4
VT2HIGH
RO
0
Set to 1, VT2 temperature exceeds high limit.
Set to 0, VT2 temperature does not exceed high limit.
3
VT2LOW
RO
0
Set to 1, VT2 temperature goes below low limit.
Set to 0, VT2 temperature does not goes below low limit.
2
1
0
OPEN
VT2THERM
VT1THERM
RO
RO
RO
0
0
0
Set to 1, VT2 is open-circuit.
Set to 1, VT2 temperature exceeds its THERM limit.
Set to 1, VT1 temperature exceeds its THERM limit.
VT1 (Local); VT2 (Remote)
F75393
-9-
May, 2008
V0.16P