Pressure
Operating Characteristics
Table 1. Operating Characteristics
(V
S
= 3.0 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2)
Characteristic
Pressure Range
(1)
Supply Voltage
(2)
Supply Current
Full Scale Span
(3)
Offset
(4)
Sensitivity
Linearity
Pressure Hysteresis (0 to 50 kPa)
Temperature Hysteresis
Temperature Coefficient of Full Scale Span
Temperature Coefficient of Offset
Temperature Coefficient of Resistance
Input Impedance
Output Impedance
Response Time
(5)
(10% to 90%)
Warm-Up Time
(6)
Offset Stability
(7)
Symbol
P
OP
V
S
I
O
V
FSS
V
OFF
ΔV/ΔΡ
—
—
—
TCV
FSS
TCV
OFF
TCR
Z
IN
Z
OUT
t
R
—
—
Min
0
—
—
45
0
—
–0.6
—
—
–0.22
—
0.31
355
750
—
—
—
Typ
—
3.0
6.0
60
20
1.2
—
±0.1
±0.5
—
±15
—
—
—
1.0
20
±0.5
Max
50
6.0
—
90
35
—
0.4
—
—
-0.16
—
0.37
505
1875
—
—
—
Units
kPa
V
DC
mAdc
mV
mV
mV/kPa
%V
FSS
%V
FSS
%V
FSS
%V
FSS
/°C
µV/°C
%Z
IN
/°C
Ω
Ω
ms
ms
%V
FSS
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
error due to device self-heating.
3. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
4. Offset (V
OFF
) is defined as the output voltage at the minimum rated pressure.
5. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
specified step change in pressure.
6. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the pressure is stabilized.
7. Offset stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
MPX53
2
Sensors
Freescale Semiconductor