11. Reliability test results
Reliability Test Items
Test
cate-
gories
Test items
1 Terminal Strength
(Pull test)
2 Mounting Strength
Pull force
Test time
Screw torque
Test time
Test methods and conditions
:
:
:
:
20N
10±1 sec.
2.5 ~ 3.5 N�½�m (M5)
10±1 sec.
Reference
Number Accept-
norms
of
ance
EIAJ ED-4701
sample number
5
5
(0:1)
(0:1)
(Aug.-2001 edition)
Test Method 401
MethodⅠ
Test Method 402
methodⅡ
Test Method 403
Reference 1
Condition code B
3 Vibration
4 Shock
5 Solderabitlity
6 Resistance to
Soldering Heat
1 High Temperature
Storage
2 Low Temperature
Storage
3 Temperature
Humidity
Storage
4 Unsaturated
Pressurized Vapor
Range of frequency : 10 ~ 500Hz
Sweeping time
: 15 min.
Acceleration
: 100m/s
2
Sweeping direction : Each X,Y,Z axis
Test time
: 6 hr. (2hr./direction)
Maximum acceleration : 5000m/s
2
Pulse width
: 1.0msec.
Direction
: Each X,Y,Z axis
Test time
: 3 times/direction
Solder temp.
: 235±5
℃
Immersion time
: 5±0.5sec.
Test time
: 1 time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Solder temp.
: 260±5
℃
Immersion time
: 10±1sec.
Test time
: 1 time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Storage temp.
: 125±5
℃
Test duration
: 1000hr.
Storage temp.
: -40±5
℃
Test duration
: 1000hr.
Storage temp.
: 85±2
℃
Relative humidity
: 85±5%
Test duration
: 1000hr.
Test temp.
: 120±2
℃
Test humidity
: 85±5%
Test duration
: 96hr.
Test temp.
:
Low temp. -40±5
℃
High temp. 125
±5 ℃
RT 5 ~ 35
℃
: High ~ RT ~ Low ~ RT
1hr. 0.5hr. 1hr. 0.5hr.
: 100 cycles
:
High temp. 100
+0
-5
5
(0:1)
Mechanical Tests
Test Method 404
Condition code B
5
(0:1)
Test Method 303
Condition code A
5
(0:1)
Test Method 302
Condition code A
5
(0:1)
Test Method 201
Test Method 202
Test Method 103
Test code C
Test Method 103
Test code E
Test Method 105
5
5
5
(0:1)
(0:1)
(0:1)
5
(0:1)
Environment Tests
5 Temperature
Cycle
5
(0:1)
Dwell time
Number of cycles
6 Thermal Shock
Test temp.
℃
Low temp. 0
℃
Used liquid : Water with ice and boiling water
Dipping time
: 5 min. par each temp.
Transfer time
: 10 sec.
Number of cycles
: 10 cycles
+5
-0
Test Method 307
method
Ⅰ
Condition code A
5
(0:1)
MS5F6013
6
13
H04-004-03a