7MBR35UB120
IGBT MODULE (U series)
1200V / 35A / PIM
IGBT Modules
Features
· Low V
CE
(sat)
· Compact Package
· P.C. Board Mount Module
· Converter Diode Bridge Dynamic Brake Circuit
Applications
· Inverter for Motoe Drive
· AC and DC Servo Drive Amplifier
· Uninterruptible Power Supply
Maximum ratings and characteristics
Absolute maximum ratings (Tc=25°C unless otherwise specified)
Item
Collector-Emitter voltage
Gate-Emitter voltage
Collector current
I
CP
-I
C
Collector power disspation
Collector-Emitter voltage
Gate-Emitter voltage
Collector current
Brake
Symbol
V
CES
V
GES
I
C
Condition
Rating
1200
±20
Continuous
1ms
Inverter
Tc=25°C
Tc=80°C
Tc=25°C
Tc=80°C
35
25
70
50
35
70
160
1200
Unit
V
V
A
-I
C
pulse
P
C
V
CES
V
GES
I
C
I
CP
1ms
1 device
W
V
V
A
Continuous
1ms
1 device
Tc=25°C
Tc=80°C
Tc=25°C
Tc=80°C
±20
25
15
50
30
115
1200
1600
Collector power disspation
Repetitive peak reverse voltage
Repetitive peak reverse voltage
Average output current
Surge current (Non-Repetitive)
I
2
t
(Non-Repetitive)
Converter
P
C
V
RRM
V
RRM
I
O
I
FSM
I
2
t
W
V
V
A
A
A
2
s
°C
°C
V
V
N·m
50Hz/60Hz sine wave
Tj=150°C, 10ms
half sine wave
35
360
648
+150
-40 to +125
AC 2500
AC 2500
3.5 *
1
T
j
Operating junction temperature
T
stg
Storage temperature
Isolation between terminal and copper base *2 V
iso
voltage between thermistor and others *3
Mounting screw torque
AC : 1 minute
*1 Recommendable value : 2.5 to 3.5 N·m (M5)
*2 All terminals should be connected together when isolation test will be done.
*3 Two thermistor terminals should be connected together, each other terminals should be