Sensing element/Gauge
■Features
Surface mount package
■Ordering
Information
FGM-6 07P G SR
FGM
Data sheet
Terminal leads configuration
Model
Length of the pressure port
3:3mm
6:6mm
Rated Pressure
(PSI)
Surface mount package
Pressure type
G:Gauge Pressure
Weight
(grams)
Weight
(grams)
0.3
0.35
Measurable pressure
range(kPa)
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
-98.07 to 103.4
-98.07 to 206.8
-98.07 to 344.7
-98.07 to 482.6
-98.07 to 827.4
Part number
3mm pressure port
FGM-302PGSR
FGM-305PGSR
FGM-307PGSR
FGM-315PGSR
FGM-330PGSR
FGM-350PGSR
FGM-370PGSR
FGM-3120PGSR
05PG
07PG
6mm pressure port
FGM-602PGSR
FGM-605PGSR
FGM-607PGSR
FGM-615PGSR
FGM-630PGSR
FGM-650PGSR
FGM-670PGSR
FGM-6120PGSR
15PG
30PG
50PG
RoHS compliance
■Specifications
Model
02PG
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Excitation current (Constant)
70PG
120PG
Unit
-
kPa
kPa
deg.C
-
mADC
13.79
-13.79
to 13.79
34.47
-34.47
to 34.47
Gauge pressure
48.26
103.4
206.8
344.7
-48.26
-98.07
-98.07
-98.07
to 48.26 to 103.4 to 206.8 to 344.7
0 to 50
Non-corrosive gases only (No liquid)
1.5
Twice of rated pressure
482.6
-98.07
to 482.6
827.4
-98.07
to 827.4
Absolute maximum rating
Maximum load pressure
Maximum excitation current
Operating temperature
Storage temperature
Operating humidity
1.5 times
of rating
pressure
-
mADC
deg.C
deg.C
%RH
mV
mV
msec.
%FS/0-
50deg.C
3.0
-20 to 100
-40 to 120
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
60 to 140 (at 0kPa to rated pressure)
Offset voltage
+/-20 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-5
TCS*
2.5
Linearity
+/-0.5
+/-0.3
Pressure hysteresis
+/-0.4
+/-0.2
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
+/-0.5
+/-0.6
+/-0.4
%FS
%FS