Unit/Water level sensor
Features
.
.
.
.
FPOW Data sheet
Applications
. Boiler
Positive and negative water pressure measurable
. Industrial instrumentation
Volt level output
Piggy-back style, pre-amplified and pre-compensated module
Pre-calibration of offset voltage and span
Part number for ordering
FPOW - 08 G
Pressure type
G : Gauge (Bipolar pressure)
Model
FPOW
Rated pressure (PSI)
Pressure type
Gauge pressure
FPOW
Model
Package configuration
Measurable pressure range (kPa)
29.4 49.0
Outer housing encapsulated sensor unit
Part number for ordering
FPOW-08G
Specifications
Model
/
Rated pressure
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Pressure media
Excitation voltage
Absolute maximum rating
Maximum load pressure
Positive pressure
Negative pressure
08G
Gauge pressure
29.4 49.0
0.3 0.5
29.4 49.0
Bath water (including bath fragrance)
5.0
Unit
kPa
kg/cm
2
kPa
VDC
kPa
kPa
VDC
196
98
Maximum excitation voltage
12
Operating temperature
20
60
Storage temperature
40
80
Operating humidity
30 80
(
No dew condensation
)
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 10
Mechanical response time
5 (For the reference)
Output voltage
0.3( 29.4kPa) 3.5(49.0kPa)
Full scale span voltage
3.2 0.1
Offset voltage
1.5 0.1
Temperature sensitivity of offset(TSO)
2.5
Temperature coefficient of sensitivity(TCS)
2.5
RH
mA
msec
V
V
V
FS/0 50
FS/0 50
1