Pre-amplified/5V Excitation/Gauge
Outline dimensions
2.54 2.54
XFPN,XFGN-6 Data sheet
Unit : mm
XFPN-6
Pressure port
1
2
3
0.8
7
6
5
7
4
3
Vent hole
Index
6
9.5
0.25
3.5
Recommended footprint for PCB
1.7
1.4
2- 1(Holes for projections)
0.8
10.3
15
X
MA
Projections
0.5
.
6
5
4
2-R0.5
2.54 2.54
6.0
9.4
1
Land-pads
Projections
1
2
3
Labelled faceplate
(Unit : mm)
Connection diagram
XFPN, XFGN-6
Vcc(DC5V)
Vcc
Vout
Vout
GND
C2
C1
Remarks :
GND
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm dis-
tance from leads.
3) 4 and 5 pins must be No Connection. Open them as float-
ing ones completely, and do NOT connect to other line or
each other.
Transfer Function
Vout=Vs (P
+ ) (Pressure Error Temperature Error Multiplier
Vs)
Vs=5.0volts
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
pressure range
Temperature Error Multiplier
6
Temperature Error Multiplier
5
4
3
2
1
0
-10
03PGV
025KPG
050KPG
100KPG
100KPGV
200KPG
0
24.5kPa
0 25kPa
0 50kPa
0 100kPa
0
100kPa
0 200kPa
0.03266
0.032
0.016
0.008
0.008
0.004
0.1
0.1
0.1
0.1
0.1
0.1
Pressure Error(kPa)
0.612
0.625
1.25
2.5
2.5
5.0
0
10
20
30
40
50
60
70
80
Temperature
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : sensor@fujikura.co.jp
6.0