 浏览型号MBM29F400BC-55PF的Datasheet PDF文件第11页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第12页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第13页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第14页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第16页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第17页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第18页浏览型号MBM29F400BC-55PF的Datasheet PDF文件第19页  
MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90  
The device will automatically power-up in the read/reset state. In this case, a command sequence is not required  
to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no  
spurious alteration of the memory content occurs during the power transition. Refer to the AC Read  
Characteristics and Waveforms for the specific timing parameters.  
Autoselect Command  
Flash memories are intended for use in applications where the local CPU alters memory contents. As such,  
manufacture and device codes must be accessible while the devices reside in the target system. PROM  
programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high  
voltage onto the address lines is not generally desired system design practice.  
The device contains an autoselect command operation to supplement traditional PROM programming  
methodology. The operation is initiated by writing the autoselect command sequence into the command register.  
Following the command write, a read cycle from address XX00H retrieves the manufacture code of 04H. A read  
cycle from address XX01H for ×16 (XX02H for ×8) returns the device code (MBM29F400TC = 23H and  
MBM29F400BC = ABH for ×8 mode; MBM29F400TC = 2223H and MBM29F400BC = 22ABH for ×16 mode).  
(See Tables 4.1 and 4.2.)  
All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit.  
Scanning the sector addresses (A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a logical  
“1” at device output DQ0 for a protected sector. The programming verification should be perform margin mode  
on the protected sector (See Tables 2 and 3).  
To terminate the operation, it is necessary to write the read/reset command sequence into the register and also  
to write the autoselect command during the operation, execute it after writing read/reset command sequence.  
Byte/Word Programming  
The device is programmed on a byte-by-byte (or word-by-word) basis. Programming is a four bus cycle operation.  
There are two “unlock” write cycles. These are followed by the program set-up command and data write cycles.  
Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the  
rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins  
programming. Upon executing the Embedded ProgramTM Algorithm command sequence the system is not  
requiredtoprovidefurthercontrolsortimings.Thedevicewillautomaticallyprovideadequateinternallygenerated  
program pulses and verify the programmed cell margin.  
The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this  
bit at which time the devices return to the read mode and addresses are no longer latched (see Table 8, Hardware  
Sequence Flags) Therefore, the devices require that a valid address to the devices be supplied by the system  
at this particular instance of time. Hence, Data Polling must be performed at the memory location which is being  
programmed.  
Any commands written to the chip during this period will be ignored. If hardware reset occurs during the  
programming operation, it is impossible to guarantee the data are being written.  
Programming is allowed in any sequence and across sector boundaries. Beware that a data “0” cannot be  
programmed back to a “1”. Attempting to do so may either hang up the device or result in an apparent success  
according to the data polling algorithm but a read from read/reset mode will show that the data is still “0”. Only  
erase operations can convert “0”s to “1”s.  
Figure 19 illustrates the Embedded Programming Algorithm using typical command strings and bus operations.  
Chip Erase  
Chip erase is a six bus cycle operation. There are two “unlock” write cycles. These are followed by writing the  
“set-up” command. Two more “unlock” write cycles are then followed by the chip erase command.  