欢迎访问ic37.com |
会员登录 免费注册
发布采购

MBM29F400TC-55PFTN 参数 Datasheet PDF下载

MBM29F400TC-55PFTN图片预览
型号: MBM29F400TC-55PFTN
PDF下载: 下载PDF文件 查看货源
内容描述: 4M ( 512K ×8 / 256K ×16 )位 [4M (512K X 8/256K X 16) BIT]
分类和应用: 闪存存储内存集成电路光电二极管
文件页数/大小: 47 页 / 522 K
品牌: FUJITSU [ FUJITSU ]
 浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第4页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第5页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第6页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第7页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第9页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第10页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第11页浏览型号MBM29F400TC-55PFTN的Datasheet PDF文件第12页  
MBM29F400TC-55/-70/-90/MBM29F400BC-55/-70/-90  
Table 2 MBM29F400TC/BC User Bus Operation (BYTE = VIH)  
DQ0 to  
DQ15  
Operation  
CE  
OE  
WE  
A0  
A1  
A6  
A9  
RESET  
Auto-Select Manufacturer Code (1)  
Auto-Select Device Code (1)  
Read (3)  
L
L
L
H
L
L
L
L
X
X
L
L
H
H
H
X
H
L
L
H
A0  
X
L
L
L
L
VID  
VID  
A9  
X
Code  
Code  
DOUT  
H
H
H
H
H
H
H
H
VID  
L
L
A1  
X
A6  
X
X
A6  
L
Standby  
X
H
H
VID  
L
HIGH-Z  
HIGH-Z  
DIN  
Output Disable  
X
X
X
Write  
A0  
X
A1  
X
A9  
VID  
VID  
X
Enable Sector Protection (2)  
Verify Sector Protection (2)  
Temporary Sector Unprotection  
Reset (Hardware)/Standby  
X
H
X
X
L
H
X
L
Code  
X
X
X
X
X
X
X
X
X
HIGH-Z  
Table 3 MBM29F400TC/BC User Bus Operation (BYTE = VIL)  
DQ15  
Operation  
CE OE WE  
A0  
A1  
A6  
A9 DQ0 to DQ7 RESET  
/A-1  
Auto-Select Manufacturer Code (1)  
Auto-Select Device Code (1)  
Read (3)  
L
L
L
H
L
L
L
L
X
X
L
L
H
H
H
X
H
L
L
L
H
A0  
X
L
L
L
L
VID  
VID  
A9  
X
Code  
Code  
DOUT  
H
H
H
H
H
H
H
H
VID  
L
L
L
A-1  
X
A1  
X
A6  
X
X
A6  
L
Standby  
X
H
H
VID  
L
HIGH-Z  
HIGH-Z  
DIN  
Output Disable  
X
X
X
X
Write  
A-1  
L
A0  
X
A1  
X
A9  
VID  
VID  
X
Enable Sector Protection (2)  
Verify Sector Protection (2)  
Temporary Sector Unprotection  
Reset (Hardware)/Standby  
X
H
X
X
L
L
H
X
L
Code  
X
X
X
X
X
X
X
X
X
X
X
HIGH-Z  
Legend: L = VIL, H = VIH, X = VIL or VIH,  
= Pulse input. See DC Characteristics for voltage levels.  
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. Refer  
to Table 7.  
2. Refer to the section on Sector Protection.  
3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations.  
8