欢迎访问ic37.com |
会员登录 免费注册
发布采购

G2PC1V560 参数 Datasheet PDF下载

G2PC1V560图片预览
型号: G2PC1V560
PDF下载: 下载PDF文件 查看货源
内容描述: 48V或24V输入1.0V , 1.2V , 1.5V , 1.8V , 2.0V , 2.5VDC , 60A输出3.3V , 45A ; 5.0V , 30A输出 [48V or 24V Input 1.0V, 1.2V, 1.5V, 1.8V, 2.0V, 2.5VDC, 60A Output 3.3V, 45A; 5.0V, 30A Output]
分类和应用:
文件页数/大小: 7 页 / 636 K
品牌: GALAXY [ GALAXY POWER, INC. ]
 浏览型号G2PC1V560的Datasheet PDF文件第1页浏览型号G2PC1V560的Datasheet PDF文件第3页浏览型号G2PC1V560的Datasheet PDF文件第4页浏览型号G2PC1V560的Datasheet PDF文件第5页浏览型号G2PC1V560的Datasheet PDF文件第6页浏览型号G2PC1V560的Datasheet PDF文件第7页  
General Specifications  
V
= 48V , T @25°C, 300 LFM Airflow, V  
=2.5V, I  
= Full Load unless otherwise noted.  
OUT  
IN  
DC  
A
OUT  
Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)  
Input Characteristics  
Parameter  
(24V Input in [brackets])  
Min  
Typ  
Max  
Units  
Operating Input Voltage  
Input Current (Model Dependent)  
Input Capacitance  
36 [18]  
48 [24]  
75 [36]  
6 [10]  
V
DC  
A
4 [9]  
2 [1]  
µF  
Input Hysteresis, Low Line  
V
DC  
Output Characteristics  
Regulation Over Line, Load & Temperature  
Voltage Ripple  
98  
102  
25  
%V  
mV  
NOM  
RMS  
Voltage Ripple, 20MHz BW  
Current Range  
85  
mV  
P–P  
0
60  
A
Current Limit Inception  
103  
140  
90  
%I  
OUT  
Short Circuit Current, Peak (see Note below)  
Output Transient Response, 50% to 75% load change, 1A/µsec  
Settling Time to ±1%  
A
5
%V  
OUT  
200  
35  
µS  
mS  
Turn-on Time to 98%Vnom  
Output Overshoot at Turn-on  
Trim Range  
0
%V  
OUT  
OUT  
OUT  
70  
110  
%V  
%V  
Overvoltage Protection, Latching  
130  
Isolation  
Isolation Test Voltage, Input/Output (Basic)  
Isolation Test Voltage, Input/Case  
Isolation Test Voltage, Output/Case  
Isolation Resistance  
2250  
2000  
500  
10  
V
V
V
DC  
DC  
DC  
M  
Features  
Overtemperature Protection, Thermal Sensor, Latching*  
110  
°C  
Switching Frequency, Fixed  
250  
kHz  
Notes: During short circuit, converter will shut down and attempt to restart once per second. The average current during this  
condition will be very low and the device can be safely left in this condition continuously. For specific output voltage  
specifications, see the corresponding detailed data sheet.  
*PCB less than 130°C  
General Specifications  
Approvals and Standards  
Operating Temperature  
Storage Temperature  
Relative Humidity  
-40°C to +100°C  
-55°C to +125°C  
UL and c-UL Recognized Component, TUV,  
UL60950, CSA 22.2 No. 950, IEC/EN 60950  
EMC Characteristics:  
10% to 95% RH,  
Non-condensing  
2 to 9Hz, 3mm disp.,  
9 to 200Hz 1g  
Designed to meet emission and immunity  
requirements per EN55022, CISPR 22, Class B,  
and CISPR 24.  
Vibration  
Material Flammability  
Weight  
UL V-0  
An external fuse shall be used to comply with the  
requirements.  
35 grams  
MTBF  
Telcordia (Bellcore) 1.6 Million Hours  
Pisces II Series, Page 2  
WWW.GALAXYPWR.COM  
Part No. 02-007 Rev. 3.0–061004